Atlantic SWH 10U M-N1 Buku Petunjuk - Halaman 4
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pemanas Air Atlantic SWH 10U M-N1. Atlantic SWH 10U M-N1 16 halaman. Electric water heater glass-lined inner tank
1. INSTALLATION - Read warning first
•
Refer to installation figures
•
WARNING: the wall plate and the head of the screws used to fix the wall plate to the wall must match to the water heater
shapes. Select the adapted screw heads as the ones provided in order that the water heater is hanged by both wall plate
spits and stands fully in contact with the wall before filling with water.
2. HYDRAULIC CONNECTION - Read warning first
•
It is necessary to clean the supply piping prior to the hydraulic connection. The connection to the hot water outlet is to be
carried out with a cast iron or steel sleeve or a dielectric connector, to avoid corrosion of the pipe (direct contact iron/copper).
The use of brass fittings is prohibited.
•
PRESSURISED INSTALLATION see figure
•
PRESSURLESS INSTALLATION see figure
with an optional special mixer tap.
•
During heating up, water dripping may occur at the valve, do not obstruct the dripping. The supplied safety device does
not meet the criteria for installation on French territory (Mainland and Overseas territories): do not use it in those territories.
3. ELECTRICAL CONNECTION - Read warning first
•
Refer to diagrams
•
The water heater can be connected and operated only on AC 230V or on AC 220-240V in accordance with the rating
plate of the appliance.
•
Connect the heater with a rigid cable with conductors 2,5mm². Use a standardised channeling (rigid or flexible conduit)
until the calibrated housing cover. Directly connect devices with a cable , or plug. (Forbidden in French territory.
•
Always connect the earth conductor of the cable to the earth ground wire or connect the earth conductor to the appropriate
terminal identified by the symbol
be longer than those of phases. The installation must be equipped, upstream of the appliance, with a bipolar cut-out device
(minimum contact distance of 3 mm fuse, breaker switch). In the case where the hydraulic connections are in insulated
material, electrical circuits shall be protected by a differential circuit breaker 30 mA adapted to local standards.
•
Thermal circuit breaker: all products are equipped with a thermostat having a thermal circuit breaker with manual reset
which cuts the power in case of overheating. In case the safety trips
a. Cut the power before any operation.
b. Remove the plastic cover.
c. Check the electrical connection.
d. Reset safety.
In case of repetitive tripping, replace the thermostat. Never bypass safety or regulation thermostat. Connect power only
on the socket or on thermostat input.
4. STARTING UP
•
NEVER POWER THE WATER HEATER WITHOUT WATER: the heating element will certainly be damaged, and
this is not covered by warranty.
.
•
Figure
Fill the tank completely. Before powering up, open the hot water taps, drain the pipes in order to
empty the air.
•
Check the tightness of the tubes and of the flange seal under the plastic cover. In case of leak, tighten moderately. Check
the operating of the hydraulic components and of the safety valve.
•
Turn the power on. After 10 to 30 minutes, depending of the capacity of the device, the water should drip from the drain.
This is normal and due to the expansion of water. Check connection leaks and seal. During heating and according to the
water quality, hot water tanks can make a bubbling noise. This noise is normal and does not indicate any defect of the unit.
If you see a continuous release of steam or hot water from the drain or when opening a faucet, turn the power off
immediately and call a professional.
5. CONTROL AND HUMAN MACHINE INTERFACE
•
Models: SWH 10A M-N1 / SWH 10U M-N1 / SWH 15A M-N1 / SWH 15U M-N1 / SWH 30A M-N1 / SWH 30U M-N1
Always install a new safety device on the cold water pipe of the water heater.
for model N1.
. This connection is compulsory for safety reasons. The earth wire green - yellow must
•
Adjusting the temperature: The temperature of the water may be adjusted by
turning the front knob. Allow half an hour for the temperature to stabilize between
settings. Maximum temperature is achieved with the knob turned fully clockwise. The
red LED light shows when the heating element is working, under control of the
thermostat, when the water reaches the preset temperature, the thermostat
deactivates the heating element automatically and Blue LED lights ON to indicate
the water is ready for shower.
•
Eco mode (depending on models): The ECO position on the regulation knob
corresponds to a water temperature of 50 - 55°C which allows more energy savings
while preventing scale build up and extending the heating element lifetime.
For the supply of a single point of use, the installation must be carried out
2