Connect the Colorfalls together using the 1½" threaded connector (included).
Begin by installing one end of the connector into the side inlet of one Colorfalls.
Align the second Colorfalls and spin it onto the threaded fitting (screwing the two
units together). Before they are completely tightened, install the double sided
gasket (included) at the end of the end of the spillway between the units. This
will create a watertight seal where the spillways meet. Pull the spillways of the
Colorfalls apart while completing the final turn of the Colorfalls body. Once you
have ensured proper alignment, press the spillways of the two units together
(sandwiching the gasket) to ensure it is in contact with both units.
1½" connector fitting
Figure 2
When plumbing multiple Color Changing Colorfalls together, use the back center
inlet on each individual Colorfalls, plugging the side inlets, regardless if you are using
one pump or multiple pumps. This will balance the flow of water going to the falls.
Note: If plumbing two different sized Colorfalls together, a ball valve must be added
on each vertical feed line to adjust the water flow into each unit.
The individual feed
lines to each Colorfalls
should be 1½" PVC. If
using one pump to feed
multiple Colorfalls, the
main feed line should
be 2" or larger. The
main feed line should
be run horizontally
along the back of the
wall with vertical 1½"
feed lines branching
off to each Colorfalls
Figure 3
(Figure 3).
Operation
Technical Data (Control Module)
Working Temperature:
0ºF -140ºF (-20°C - 60ºC)
Output: 3 circuits (R/G/B)
4
1½"
1½"
2" Feed
Lines
Input Power: AC12V
Output Power: DC12V, 80 watts max
Output Current: 2A /circuit
Installation Requirements
1. The Control Module is weather-resistant with an IP54 rating. Do not submerse it
or expose it to heavy rainfall. It must be mounted off the ground close to the
power source. Failure to do so will void the warranty.
2. Remove the red protective cap from the top of the control module and install
the antenna. Thread the black antenna on until snug, making sure it seals
against the gasket.
3. Install the control box in a well ventilated area to ensure that the module
operates in within its working temperature specified above.
4. Verify that the control module input voltage is 12 volt AC. We recommend that
you use the transformer provided with this unit.
5. Ensure that all cable connections are secure.
6. Do not connect the power before the cord connections are finished.
7. Do not cut or alter the cord between the Colorfalls and the Control Module.
8. The remote control requires three (2) AAA batteries (not included). Do not
touch the face of the remote while installing batteries.
Connecting the Light Bar
The Colorfalls light bar will not operate if plugs are aligned incorrectly. The six
pronged connectors have raised arrows that indicate proper alignment. Follow
the connecting chart below to connect all cables.
Ensure that the unit is not plugged in while connecting.
LED Light Strip
Atlantic's CCCM05 Master Controller (sold separately) enables up to five individual
Color Changing light bars to be synchronized to change colors at the same time
using one remote. In this application, only one Control Module and one remote
are required. Use a Control Module and remote from any Colorfalls and it will
control all light bars when used with the CCCM05 Master Controller. Replace the
transformer from your Colorfalls with the 60 watt transformer from the Master
Controller, and connect the 5-Way splitter supplied with the CCCM05 between the
Control Module and the light bars. See the connecting chart below for details.
Control Module
Transformer
LED Light Strip
Transformer
Control Module
(2) 3-Way Splitters
5