Juga untuk Bosch KDN series: Petunjuk Penggunaan Manual (27 halaman), Petunjuk Penggunaan Manual (23 halaman), Panduan Petunjuk Pengoperasian (24 halaman), Petunjuk Penggunaan Manual (21 halaman), Petunjuk Instalasi dan Penggunaan Manual (18 halaman), Petunjuk Pengoperasian dan Pemasangan (17 halaman), Petunjuk Penggunaan Manual (29 halaman)

Bosch KDN series Petunjuk Penggunaan Manual
en
Ventilation
Fig. $
The air on the rear panel and on the side
panels of the appliance heats up.
Conduction of the heated air must
not be obstructed. Otherwise,
the refrigerating unit must work harder.
This increases power consumption.
Therefore: Never cover or block
the ventilation openings!
Connecting
the appliance
After installing the appliance, wait at least
1 hour until the appliance is switched on.
During transportation the oil in
the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for the
first time, clean the interior of the
appliance (see chapter "Cleaning
the appliance").
Electrical connection
The socket must be near the appliance
and also freely accessible following
installation of the appliance.
8
m
Warning
Risk of electric shock!
If the length of the mains cable is
inadequate, never use multiple sockets
or extension leads. Instead, please
contact Customer Service for
alternatives.
The appliance complies with protection
class I. Connect the appliance to 220–
240 V/50 Hz alternating current via a
correctly installed socket with protective
conductor. The socket must be protected
by a 10 A to 16 A fuse.
For appliances operated in non-
European countries, check whether the
indicated voltage and current type match
the values of your electricity supply. This
information can be found on the rating
plate, Fig. ).
m
Warning
Never connect the appliance
to electronic energy saver plugs.
Our appliances can be used with mains
and sine-controlled inverters. Mains-
controlled inverters are used
for photovoltaic systems which
are connected directly to the national
grid. Sine-controlled inverters must be
used for isolated applications (e.g. on
ships or in mountain lodges) which are
not connected directly to the national
grid.