4 Operation
To determine which temperature control you are
using (method 2)
You can see on the home screen which temperature control you are
using.
18 Feb 2018
55
a2
18
b
1.6
21
bar
a1
45
a1
Heat emitter of the main zone (in this example Underfloor
heating)
a2
Heat emitter of the additional zone (in this example
Radiator). If no icon is displayed, there is no additional
zone.
b
Room thermostat type of the main zone:
If b=...
Then the temperature control is...
Main zone
Room thermostat
control
External room
thermostat control
No icon
Leaving water
temperature control
4.4.4

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
1
Room
2 Adjust the desired room temperature.
a
b
1
21
°C
Room
a Actual room temperature
b Desired room temperature
If scheduling is on after changing the desired room temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired room temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off room temperature scheduling
1 Go to [1.1]: Room > Schedule.
2 Select No.
User reference guide
8
22:19
6
Additional zone (if
any)
External room
thermostat control
Leaving water
temperature control
+
4.4.5
To change the desired leaving water
temperature
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Only adjust the leaving water temperature settings in case
of problems.
You can use the leaving water temperature setpoint screen to read
out and adjust the desired leaving water temperature.
1 Go to [2]: Main zone or [3]: Additional zone.
2
Main zone
3
Additional zone
2 Adjust the desired leaving water temperature.
a
b
2
35
°C
Main zone
a
b
3
45
°C
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
If scheduling is on after changing the desired leaving water
temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired leaving water temperature will return to its scheduled
value whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off leaving water temperature scheduling
1 Go to one of the following:
▪ [2.1]: Main zone > Schedule
▪ [3.1]: Additional zone > Schedule
2 Select No.
To enable weather-dependent operation for the leaving water
temperature
See
"4.8 Weather-dependent operation" on
EHBH/X04+08DA + EHVH/X04+08S18+23DA + EHVH/
+
+
page 15.
X04+08S18+23DJ
Daikin Altherma 3 R F+W
4P495250-1B – 2019.06