Electrolux Frigidaire 76F49-AM21 Petunjuk Instalasi & Panduan Pengguna - Halaman 9

Jelajahi secara online atau unduh pdf Petunjuk Instalasi & Panduan Pengguna untuk Kap Ventilasi Electrolux Frigidaire 76F49-AM21. Electrolux Frigidaire 76F49-AM21 17 halaman. 30"

Information
 Sufficient air is needed for proper combustion and exhaustion of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Ductless fans must
always be vented to the outdoors.
When assessing the air pressure, the entire ventilation system in the house/apartment
must be taken into account, e.g. hob and/or gas cooker, this rule does not apply.
Government regulations must be observed for the conveyance of exhaust air. If the
extractor hood is used in circulating air mode with activated carbon filter, there are no
operating restrictions.
If you choose extraction-air mode,choose A or B for venting air, and install check valve
on the vent hole you choose.
Prepare the installation:
Ensure the power has been turned off before beginning this installation. Plug must be
assembled in places easy to drag and insert.
To install this hood you will require two assistants. You will need following tools and
material to complete this installation.
Tools you will need:
 Drill appropriate to your wall
 Phillips Screwdriver
 Tape Measure
 Hand Saw or Jig Saw
Installation work and electrical wiring must
be done by qualified person(s) in accordance
with all applicable codes and standards,
including fire rated construction.
Do not discharge the exhaust air into a flue
from other appliances burning gas or other
fuels.
Regulations concerning the discharge of air
have to be fulfilled.
The cooker hood must be placed at a
minimum distance of 25.6" above the
cooking surface of a hob.
The cooker hood must be placed at a
maximum distance of 29.5" above the
cooking surface of a hob.
A
B
24/30/36"
9
Min. 25.6"
Max. 29.5"