Electrolux ICON RH36WC60GS Panduan Pemasangan, Penggunaan & Perawatan - Halaman 5

Jelajahi secara online atau unduh pdf Panduan Pemasangan, Penggunaan & Perawatan untuk Kap Ventilasi Electrolux ICON RH36WC60GS. Electrolux ICON RH36WC60GS 22 halaman. 30” et 36” hotte aspirante
Juga untuk Electrolux ICON RH36WC60GS: Spesifikasi (2 halaman), Katalog Suku Cadang Pabrik (4 halaman), Panduan Pemasangan, Penggunaan & Perawatan (21 halaman), Panduan Pemasangan, Penggunaan & Perawatan (22 halaman), Panduan Penggunaan & Perawatan (44 halaman), (Bahasa Inggris) Panduan Pemasangan, Penggunaan, dan Perawatan (22 halaman), (Bahasa Prancis) Panduan Pemasangan, Penggunaan, dan Pemasangan (22 halaman)

Electrolux ICON RH36WC60GS Panduan Pemasangan, Penggunaan & Perawatan
Important safety Instructions - Electrical & Installation
READ AND SAVE THESE INSTRUCTIONS
Electrical & Installation requirements
Electrical r
Electrical requir
Electrical r
Electrical r
Electrical r
equir
equir
equirements
equir
ements
ements
ements
ements
IMPORT T T T T ANT
IMPOR
IMPOR
ANT
ANT
IMPOR
IMPOR
ANT
ANT
Observe all governing codes and ordinances.
It is the customer' s responsibility:
To contact a quali ed electrical installer.
To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 — latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code, Part 1 and
C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it
is recommended that a quali ed electrician determine
that the ground path is adequate.
Do not ground to a gas pipe.
Check with a quali ed electrician if you are not sure
range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPOR
IMPOR
IMPOR
IMPORT T T T T ANT
IMPOR
ANT
ANT
ANT
ANT
Save Installation Instructions for electrical inspector' s
use.
The range hood must be connected with copper wire
only.
The range hood should be connected directly to the
fused disconnect (Or circuit breaker) box through
metal electrical conduit.
Wire sizes must conform to the requirements of the
National Electrical Code ANSI/NFPA 70 — latest edi-
tion*, or CSA Standards C22.1-94, Canadian Electri-
cal Code Part 1 and C22.2 No. 0-M91 - latest edi-
tion** and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be
provided at each end of the power supply conduit (at
the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park Quincy,
Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleve-
land, Ohio 44131-5575

Before installing the hood

1. 1. 1. 1. 1. For the most e cient air ow exhaust, use a
straight run or as few elbows as possible.
Vent unit to outside of building and recirculating.
2. 2. 2. 2. 2. At least two people are necessary for installation.
3. 3. 3. 3. 3. The hood is tted with Screws and Drywall
Anchors suitable for most surfaces, consult a
Quali ed Installer, check if they perfectly t with
your cabinet/wall.
4. 4. 4. 4. 4. Do not use ex ducting.
5. 5. 5. 5. 5. COLD WEATHER installations should have an
additional backdraft damper that is already installed
to minimize backward cold air ow and a nonmetallic
thermal break to minimize conduction of outside
temperatures as part of the ductwork. The
damper should be on the cold air side of the
thermal break.
The break should be as close as possible to
where the ducting enters the heated portion of
the house.
6. 6. 6. 6. 6. Make up air: Local building codes may require the
use of Make-Up Air Systems when using Ducted
Ventilation Systems greater than speci ed CFM of
air movement.
The speci ed CFM varies from locale to locale.
Consult your HVAC professional for speci c
requirements in your area.
requirements
5 5 5 5 5