Atlantic Ultraviolet Sanidyne Prime 40-0673A Panduan Pemilik - Halaman 12

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Aksesori Atlantic Ultraviolet Sanidyne Prime 40-0673A. Atlantic Ultraviolet Sanidyne Prime 40-0673A 16 halaman. Ultraviolet portable area sanitizers

Atlantic Ultraviolet Sanidyne Prime 40-0673A Panduan Pemilik
5. Re-install the top cover and tighten the four thumbscrews.
6. Replace the storage cover and secure using the three latches.
7. Reconnect Sanidyne
ultraviolet rays are harmful to the eyes and skin.
Wear personal protection equipment, then verify operation by viewing lamp(s) as explained in the "Testing Unit Operation"
8.
section on Page 9. If the fixture is not operating properly, go to "Troubleshooting" section on Pages 12–13.
B

reaKage

Broken Quartz is SHARP.
D
m
isPosal of
erCury
Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added
lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and
recycling of lamps containing mercury, along with Federal and State requirements visit LampRecycle.org. For more
information on STER-L-RAY

TROUBLESHOOTING

Always disconnect power to the fixture before performing any service or maintenance.
IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
IMPORTANT: This fixture is to be serviced ONLY by qualified and factory authorized personnel.
Problem
Sanidyne
Prime
®
not operating
lamp
STER-L-RAY
®
not operating
Sanidyne
Prime
®
fails to shut off
12
Prime to utility power, and restart.
®
Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal
Wear protective gloves when handling broken ultraviolet lamps. In the event of breakage, DO NOT
use a household vacuum cleaner to pick up fragments of the lamp. Sweep up debris into a plastic
bag and dispose of in accordance with local and /or state regulations.
a
l
DDeD
amPs
Germicidal Ultraviolet Lamps, visit Ultraviolet.com or BuyUltraviolet.com.
®
Table 1 – Troubleshooting
Possible Cause
Power disconnected
Fuse
Germicidal lamp faulty
STER-L-RAY
®
Germicidal Lamp
®
STER-L-RAY
not properly seated
Loose Connection
Ballast not functioning
Surelite
TM
Timer assembly faulty
Corrective Action
Verify that the fixture is connected to a live power source.
Remove power connector to check and replace fuse
if necessary. (See Page 13)
Swap suspect lamp, with lamp known to be good. If
suspect lamp does not operate, replace lamp.
Confirm connection between lamp and lampholder is tight, and
that lamp is making full contact with lampholder.
Inspect for loose or disconnected wires.
Disconnect the fixture from utility power.
Then replace ballast
Wearing protective clothing and face shield, enter
area, and disconnect power to unit. Call factory for
technical service.