Electrolux RH30WC40GS Brosur & Spesifikasi - Halaman 2

Jelajahi secara online atau unduh pdf Brosur & Spesifikasi untuk Kap Ventilasi Electrolux RH30WC40GS. Electrolux RH30WC40GS 2 halaman. Universal/multiflex
Juga untuk Electrolux RH30WC40GS: Panduan Pemasangan, Penggunaan & Perawatan (19 halaman), Katalog Suku Cadang Pabrik (4 halaman)

Electrolux RH30WC40GS Brosur & Spesifikasi
Under-Cabinet Hood
RH30WC40G S
30" Under-Cabinet Hood Specifications
Product Weight – 27 Lbs.
Wall-Mount Installation – can be ducted vertically
or horizontally.
Ventilation system is preset to recirculate air inside with no ducting
system required. Exhausting air outside is optional, using either vertical
or horizontal ducting sytem. (Refer to Ducted Option Specifications for
outside ventilation.)
Sones Rating – 6.6
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.36 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 2.89 Amps
Always consult local and national electric codes. Check local
building codes for installation requirements, as they may vary per locale.
Connect vent hood with copper wire only.
Minimum installation height allowed from bottom of hood to cooking
surface is 24" - 30" for electric and 30" for gas. (NOT more than 36"
recommended.)
To improve performance, optional Charcoal Filter (PN # RHCF400GS)
recommended for use with recirculating system.
Electrolux Major Appliances, N.A.
5855 Terry Fox Way
Mississauga, ON L5V 3E4
CANADA
RH30WC40GS 12/10
Ducted Option Specifications
For outside ventilation.
Exhaust Duct Required – 7" round or 3-1/4" x 10"
To accommodate pre-existing, off-center ductwork, vent hood can be
installed up to one inch on either side of hood center. In extreme
off-center installation, one end of duct connector can be modified to
clear electrical cable clamp.
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
Use metallic flex ducting only to connect rigid duct directly to transitions
(if allowed by code).
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
Cold weather installations should have additional backdraft damper
installed.
Refer to installation instructions on web for detailed duct preparation and
converting exhaust vent blower system for exterior exhaust ventilation.
Note: For planning purposes only. Refer to Product Installation Guide
Optional Accessories
Charcoal Filter – (PN # RHCF400GS).
1-800-265-8352
electroluxappliances.ca
© 2010 Electrolux Home Products, Inc.
on the web at electroluxappliances.ca for detailed instructions.
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Printed in Canada