Electrolux RH30WC55GSB Panduan Pemasangan, Penggunaan & Perawatan - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Pemasangan, Penggunaan & Perawatan untuk Kap Ventilasi Electrolux RH30WC55GSB. Electrolux RH30WC55GSB 21 halaman. 30" and 36" free-standing range hood

8 8 8 8 8
Installing the hood

Examples of possible ducting

Ductwork installation guidelines

For safety reasons, ducting should vent directly
outdoors (not into an attic, underneath the house,
into the garage or into any enclosed space).
Keep duct runs as short and straight as possible.
Duct ttings (elbows and transitions) reduce air ow
e ciency.
Back to back elbows and "S" turns give very poor
delivery and are not recommended.
A short straight length of duct at the inlet of the
remote blower gives the best delivery.
Transition to duct from the integral blower or remote
duct transition as close to the downdraft as is pos-
sible.
In order of preference, use
1st. 10" round duct
2nd. 8" round duct
3rd. 3-1/4" x 14" duct
4th. 7" round duct
5th. 3-1/4" x l0" duct
6th. 6" round duct
The use of exible metal round duct should only be
used when no other duct tting exists. Limit use to
short lengths and do not crush when making
corners.

Ductwork and wiring locations

Ductwork and wiring locations
Ductwork and wiring locations
Ductwork and wiring locations
Ductwork and wiring locations
Determine the exact location of the vent hood.
Locate the template packed with the literature.
Installation height: 30" gas cooktop/range or 24"
to 30" electric cooktop/range.
Use a level to draw a horizontal straight pencil line
on the wall, which is your desired
installationheight.
Find the centerline of the cooktop. Use a level to
draw a vertical straight pencil line on the wall.
CHECK TO BE SURE THE LINE IS PERFECTLY Y Y Y Y
CHECK TO BE SURE THE LINE IS PERFECTL
CHECK TO BE SURE THE LINE IS PERFECTL
CHECK TO BE SURE THE LINE IS PERFECTL
CHECK TO BE SURE THE LINE IS PERFECTL
PERPERNDICULAR.
PERPERNDICULAR.
PERPERNDICULAR.
PERPERNDICULAR.
PERPERNDICULAR.