OPERATION & MAINTENANCE
OPERATION
IMPORTANT: The Edison Screw lamps may have come loose during transportation.
Ensure that lamps are tightened firmly into the socket before power is applied.
MODELS: REHR6*
The operation of the light and the two-speed fan are controlled by the drawer action. (see diagram)
MODELS: WRH605I* WRH608I* WRR614*A WRH908I*
The operation of the lights and the three speed fans are controlled by the drawer action. (see diagram)
3 SPEED MODELS
2 SPEED MODEL
FAN SPEED
3
2
1
OFF
TO REPLACE LIGHT GLOBES
1. Open drawer and remove filter.
2. Turn mains switch off before removing lamp.
Replace with 28W maximum E14 candle lamp. Depending on model will require 1 or 2 globes.
The lamp assembly includes a silicone seal, this must be replaced when a new lamp is used. The silicone seal is placed over
the lamp thread and then the lamp is screwed into the holder. Ensure replacement lamp is tightened firmly.
Replacement lamps from Electrolux Parts Centres are supplied with silicone seals.
P7