Electrolux WRJ611U Panduan Instalasi dan Pengoperasian - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pengoperasian untuk Kap Ventilasi Electrolux WRJ611U. Electrolux WRJ611U 4 halaman. Universal cooker hood
Juga untuk Electrolux WRJ611U: Panduan Instalasi dan Pengoperasian (4 halaman)

Electrolux WRJ611U Panduan Instalasi dan Pengoperasian
Stainless Steel Models
Before installing the cooker hood, remove all protective plastic covering from stainless steel surfaces.
Use at least 4 screws (not provided) and the mounting holes provided to securely mount the cooker hood. Make sure that the cooker hood is level
and free from twist.
Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.
300
25
25
30
143
Setting of circulation air door - single fan models
EXHAUST
RECIRCULATE
IMPORTANT: SET CIRCULATING MODES BEFORE INSTALLING THE HOLE PLUGS.
Recommended
Top Fixing Points
(use 2 from each end)
30
79
105
60
c L
100
9 0 c m
w i d e
n o m
m o d
i n a l w
e l s
i d t h
8 9 8
6 0 c m
w i d e
n o m
m o d
i n a l
e l s
w i d t
h 5 9
Top and Rear Exhaust Outlets
160
8
Ducted installation
Select required exhaust outlet, remove hole
plug and snap fit flue exhaust collar.
Setting of circulation air doors - dual fan models
EXHAUST
EXHAUST
RECIRCULATE
RECIRCULATE
Air Recirculating Outlet
25
35
500
Recommended
Rear Fixing Points (4)
The maximum space between
the wall and screw cap is 5mm