Juga untuk Electrolux #: Panduan Petunjuk Instalasi (8 halaman), Panduan Penggunaan & Perawatan (20 halaman), Panduan Penggunaan & Perawatan (36 halaman), Panduan Penggunaan & Perawatan (24 halaman), Panduan Penggunaan & Perawatan (38 halaman), Buku Resep (17 halaman), Buklet Instruksi (12 halaman), Panduan Penggunaan & Perawatan (20 halaman), Buku Instruksi (16 halaman), Buku Instruksi (12 halaman), Panduan Pengenalan (16 halaman), Panduan Pengguna (11 halaman), Panduan Penggunaan & Perawatan (26 halaman), Panduan Penggunaan & Perawatan (38 halaman), Panduan Pemilik (9 halaman), Panduan Penggunaan dan Perawatan (16 halaman), Panduan Penggunaan dan Perawatan (16 halaman), Panduan Petunjuk Instalasi (21 halaman), Panduan Pemilik (16 halaman), Panduan Penggunaan dan Perawatan (16 halaman)

Electrolux # Panduan Servis
GLMV169GSB
GLMV169GBB
GLMV169GQB
PLMVZ169GCB/C
7. Disconnect the connector CN-F from the control unit.
8. Remove one () screw holding the hood duct to the oven
cavity front plate.
9. Release the 6-pin connector and the 3-pin connector of
the main harness A from the hood duct.
0.Disconnect the wire leads from the fan motor and chassis
support, and release the wire leads from holes of the
hood duct.
.Remove the two (2) unit mounting screws from the
chassis support (right side) and the hood duct (left
side).
2.Remove the one () screw holding the chassis
support.
3.Remove the chassis support.
4.Remove the hood duct from the oven cavity by lifting
it up.
5.Screw the oven lamp off from the lamp socket.
. Disconnect the power supply cord , remove the oven
from wall and remove outer case (Refer to procedure
of "Removal of Oven from Wall" and "Outer case
Removal".)
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the wire leads from the fan motor and the
chassis support, and release them from the holes of
hood duct.
5. Remove the one () screw holding the hood duct to the
oven cavity front plate, and lift up the fan motor side of
the hood duct.
6. Remove the one () screw holding the capacitor holder
to the hood intake duct.
7. Disconnect the high voltage wire leads of the high voltage
rectifier assembly from the magnetron.
8. Disconnect the filament lead of the transformer from the
HIGH VOLTAGE RECTIFIER AND HIGH VOLTAGE CAPACITOR REMOVAL
. Disconnect the power supply cord , remove the oven
from wall and remove outer case (Refer to procedure
of "Removal of Oven from Wall" and "Outer case
Removal".)
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the wire leads from the fan motor and the
chassis support, and release them from the holes of
hood duct.
5. Remove the one () screw holding the hood duct to the
oven cavity front flange, and lift up the fan motor side of
the hood duct.
6. Disconnect the high voltage wire leads with high voltage
rectifier from the magnetron.
. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure
of "Removal of Oven from Wall" and "Outer case
Removal")
2. Open the door and block it open.
3. Discharge high voltage capacitor.

MAGNETRON REMOVAL

HOOD FAN THERMAL CUT-OUT REMOVAL
36
6.Remove the lamp socket from the lamp angle.
7.Pull the wire leads from the oven lamp socket by pushing
the terminal hole of the oven lamp socket with a small
flat type screw driver.
8.Now, the oven lamp socket is free.
9.Release the harness of the AH sensor assembly from
three (3) wire holders of the hood duct.
20.Remove two (2) screws holding the AH sensor assembly
to the hood duct.
2.Now, the AH sensor assembly is free.
Wire lead
magnetron.
9. Remove the power transformer from the right base plate,
referring to "POWER TRANSFORMER REMOVAL".
0.
Carefully remove four (4) mounting screws holding
the magnetron to waveguide. When removing the screws
hold the magnetron to prevent it from falling.
. Remove the magnetron from the unit with care so the
magnetron tube should not be hit by any metal object
around the tube.
2. Remove the one () screw holding the magnetron air
guide to the magnetron.
3. Remove the magnetron air guide
CAUTION: WHEN REPLACING THE MAGNETRON, BE
SURE THE R.F. GASKET IS IN PLACE AND
MOUNTING SCREWS ARE TIGHTENED SE-
CURELY.
7. Disconnect filament lead of the transformer from high
voltage capacitor.
8. Disconnect high voltage wire from capacitor.
9. Remove one () screw holding capacitor holder and
high voltage rectifier to the hood intake duct.
0. Disconnect the high voltage rectifier assembly from the
high voltage capacitor.
. Now, the high voltage rectifier assembly is free.
2.
Remove capacitor from the holder.
3. Now, the high voltage capacitor is free.
CAUTION: WHEN REPLACING THE HIGH VOLTAGE
RECTIFIER ASSEMBLY, THE GROUND SIDE
TERMINAL MUST BE SECURED FIRMLY WITH
A GROUNDING SCREW.
4. Disconnect the wire leads from the hood fan thermal
cut-out.
5. Remove one () screw holding the thermal cut-out to the
right base plate.
6. Remove the hood fan thermal cut-out from the right
base plate.
7. Now, the hood fan thermal cut-out is free.
Oven lamp
socket
Terminal
Terminal hole
Flate type small