Atlas FAP62T Petunjuk Instalasi
Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Pembicara Atlas FAP62T. Atlas FAP62T 1 halaman. Strategyseries ii
Juga untuk Atlas FAP62T: Brosur (5 halaman), Spesifikasi (4 halaman), Manual (5 halaman)
FAP62T
Installation Instructions
Mounting Template
11" Diameter
6. Insert enclosure through front of tile. Using standard #2 Phillips screwdriver or screw-gun, tighten four dogleg assemblies
Atlas Sound strongly suggests that a support wire be installed from this support point to a suitable anchor point above ceiling grid.
2. Place tile bridge rails and C-ring through hole. Use V-shaped edge of C-ring to align tile bridge assembly above ceiling
3. Bring service loop from rear of tile, through the tile bridge / C-ring to access panel located on the side of the enclosure. Terminate service loop to Phoenix style
4. Insert enclosure into hole. Using standard #2 Phillips screwdriver or screw-gun, tighten four dogleg assemblies until they engage the C-ring assembly.
Use of optional FAP62-TR
in new construction. Bracket mounts between 16" or 24" OC studs and includes a
1. Bring service loop through hole in ceiling provided by pre-construction bracket to access panel located on side of the enclosure. Terminate service
2. Insert speaker assembly into hole. Using standard #2 Phillips screwdriver or screw-gun, tighten four dogleg assemblies until they engage the ring provided
NOTE: Doglegs will accommodate ceiling material thickness up to 1
NOTE: UL recognized conduit clamp must be used for conduit connections. Cable connection cavity is not intended to be used as a junction box.
Auxiliary Suspension Point
Dogleg In Normal Position
Tile Bridge
Ceiling Material up to 1-1/4"
Typical Parallel Hookup of Full Range 70.7/100V Speakers
Amplifier
Typical 120 Watt 70.7V Output
The Atlas Sound Strategy Series
construction drop ceiling or drywall materials.
2. Align adjustable dual rail & C-ring assembly on rear of tile in desired position.
3. Using the template provided, mark cut out circle with marker and cut hole.
4. Affix C-ring assembly to rails using screws provided and position assembly on rear of ceiling tile.
Replace tile into grid. Be sure formed ends of tile bridge rails engage T-bar tile support rails.
5. Bring service loop from rear of tile, through the tile bridge/C-ring to the access panel located on side of enclosure.
Terminate the service loop to Phoenix style connector provided (please note polarity).
Combination knockouts are provided to facilitate conduit.
until they engage the C-ring assembly. DO NOT OVER-TIGHTEN DOGLEG SCREWS!
7. Adjust front mounted switch to desired wattage tap setting or 8Ω* (See important note regarding 8Ω operation)
8. Install press-fit grille into front bezel ring. Push baffle upwards until it is flush with the bezel ring.
9. For safety and seismic considerations a suspension ring is integrated into the input panel section of unit.
In drop tile applications, this wire can usually be installed from an adjacent tile access near speaker location.
Dry Wall ("Hard Deck") Installation
1. Using the template provided, mark cut out circle in desired mounting location and cut hole. (11" FAP62T)
(alignment screws provided are not required for this type of installation)
connector provided (please note polarity). Combination knockouts are provided to facilitate conduit.
DO NOT OVER-TIGHTEN DOGLEG SCREWS!
5. Adjust front mounted switch to desired wattage tap setting or 8Ω* (See important note regarding 8Ω operation)
6. Install press-fit grille into front bezel ring. Push baffle upwards until it is flush with the bezel ring.
New Construction (Drywall Ceilings)
(for use with FAP62T) new construction bracket essentially reserves a speaker mounting location prior to drywall installation
1
around. For final installation, please follow these instructions:
Note: Tile bridge components are not used in new construction applications where new construction bracket is utilized.
loop to Phoenix style connector provided (please note polarity). Combination knockouts are provided to facilitate conduit.
on the new construction bracket. DO NOT OVER-TIGHTEN DOGLEG SCREWS!
3. Adjust front mounted switch to desired wattage tap setting or 8Ω* (See important note regarding 8Ω operation)
4. Install press-fit grille into front bezel ring. Push baffle upwards until it is flush with the bezel ring.
Auxiliary Suspension Point
Auxiliary Suspension Point
FAP62-TR has not been evaluated by UL Laboratories
1
Dogleg In Inverted Position
Dogleg In Normal Position
Tile Bridge
as shown. DO NOT OVER-TIGHTEN DOGLEGS IN EITHER CONFIGURATION!
Ceiling Material up to 1-1/4"
Ceiling Material up to 2"
NOTE: *DO NOT USE 8Ω SETTING WITH 70.7V / 100V SySTEMS! *DO NOT OVERPOWER IN 8Ω CONFIGURATION!
AMPLIFIER OUTPUT SHOULD NOT ExCEED 32 W RMS @ 8Ω PER SPEAkER
FREQUENCy RESPONSE: 90Hz - 20kHz SENSITIVITy: 88dB (1W / 1M)
Typical Parallel Hookup of Full Range 70.7/100V Speakers
Amplifier
Typical 120 Watt 70.7V Output
Tap Wattage Total: 64 Watts
Auxiliary Suspension Point
Input
Dogleg In Inverted Position
Tile Bridge
Ceiling Material up to 2"
®
II assembly mounts easily into existing
Drop Tile Ceiling
Installation
1. Remove 2' x 2' or 2' x 4' tile.
(11" FAP62T)
⁄
" downward lip to provide a template for drywall installers to cut
3
8
FAP62TB
Full Range
16W @ 70.7V
Tile Bridge
⁄
" as shipped from factory. For thicker ceiling materials (up to 2") simply unscrew and flip doglegs
1
4
Auxiliary Suspension Point
+
-
+
-
+
-
FAP62T-B
FAP62T-B
FAP62T-B
Full Range
Full Range
Full Range
+
16W @ 70.7V
16W @ 70.7V
16W @ 70.7V
-
Dogleg In Normal Position
Typical Parallel Hookup of Full Range 70.7/100V Speakers
Amplifier
Typical 120 Watt 70.7V Output
ATS001131 RevF 12/08
Installation Instructions
Painting Shield
10
⁄
" Diameter
1
2
+
-
FAP62TB
FAP62T-B
Full Range
Full Range
16W @ 70.7V
16W @ 70.7V
Dogleg In Inverted Position
Tile Bridge
Ceiling Material up to 1-1/4"
FAP62T
ATS001131 RevD 5/08
Auxiliary Suspension Point
Tile Bridge
Ceiling Material up to 2"