FAULTS ANS SOLUTIONS
Electrical feeding
If the equipment does not work, the error is most likely due to an incorrect terminal power
supply.
1 - Check that it has been connected to a functional electrical outlet.
2 - Check that the current is compatible with the equipment and that the terminal block ca-
bles are connected according to the electrical diagram specified in this manual.
3- Check that voltage (230Vx1) reaches the equipment. If not, check the power cables.
Considerations:
- If the equipment stops recirculating air, check the level of the cyclone filter tank. If it is com-
pletely full, it must be emptied so that it can perform the function and allow air to circulate
through the equipment.
- If, once the tank has been emptied, the fan still does not work, it must be replaced with a
new one.
- If the UV light does not work, but the rest of the components do, check that the cables of
the UV Source are correctly connected.
- If the fan turns but does not blow air and the cyclonic filter tank is empty, the G4 filter must
be changed.