Advanced Radio Air Safe Panduan Pengguna - Halaman 10
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Peralatan Perekaman Advanced Radio Air Safe. Advanced Radio Air Safe 12 halaman. Failsafe gear sequencer
Important Sequencer Rules
1) The Air Safe sequencer gives you the ability to slow servos on each output channel.
Smooth Flite also allows you to (set wait times) for slower linear devices and air values. Correct
understanding of how these two features work together is important to unleashing the power in the
Smooth Flite sequencer.
Here are the rules.
If a sequence step has a servo channel that subscribes to "Global Servo Speed " then the complete step
takes the duration of the "Global Servo Speed " + any "Wait To Next Step" BEFORE moving to the next
step.
In other words the servo is played at "Servo Speed" then the "Wait To Next Step" is added to the step BE-
FORE moving on to the next step.
Example 1:
a) Slowest Servo Speed set to 5.
b) Wait To Next Step set to 2.0 seconds
c) Total step time (approx 1 second) + 2.0 = 3.0 seconds
Example 2:
a) All servos Speed set 0.0
b) Wait To Next Step set to 2.0 seconds
c) Total step time 0.0 + 2.0 = 2.0 seconds
In this example it will appear as if the step was missed.
Example 3:
a) All servos Speed set 0.0
b) Wait To Next Step set to 0.0 seconds
c) Total step time 0.0 + 0.0 = 0.0 seconds
Air Safe with Smooth Flite 26
Air Safe can be connected to an auxiliary input (4) on the Smooth Flite 26. When Airsafe is connected to
one of the telemetry inputs on the Smooth Flite 26 it passes telemetry data to the main Smooth Flite unit.
This allows the Air Safe to act as an air safety system for the main sequencer in the Smooth Flite unit. To
operate this feature you will need Smooth Flite software 5.5 or higher loaded into the Smooth Flite.
10