7.5 SET-UP AND CONFIGURATION OF THE ELECTRONIC CONTROL
SELECT THE OPERATING MODE :
Press and hold the
MODE
Select the Operation mode DISEPNSE ('dISP') or CHAIN ('ChA') by using the UP/DOWN keys and then press
continue.
MODE
According to which
unit accordingly. Use
MODE
parameter:
Parameter
Display
Number of
Lubrication Cycles
Standby Interval
Standby
Multiplication
Factor
Number of Micro-
Pumps
Micropump
Activen and Air
On-Time
Min air pressure
Max air pressure
key for at least 2 seconds. The unit will go into its set-up mode.
is selected the menu will vary. Follow the step-by-step parameter guide below to setup the
to step to the next parameter and UP/DOWN keys to vary the setting on the current
CHAIN MODE PARAMETERS
Number of times the pumps are activated
during the lubrication cycle. From 0001 a 9999.
Determines the length of the Standby intervals
by counting impulses from remote switch.
Multiplies the previous value by 1, 10 , 100 or
1000 to obtain upto 9,999,000 standby
impulses
Number of Micropumps installed on the system
with Flow Sensing. Setting this to 0 will disable
flow sensing on all micropumps. If you set less
than the number of micropumps installed than
the nearest ones will be monitored, while the
furthest will remain unmonitored. EG. Setting 5
of a 6 pump system will result in the last pump
not being monitored..
During the lubrication cycle, the system will
trigger a lubrication shot with each impulse.
This setting determines the length of the
lubrication Shot and how long the air will
remain on for.
Ensure that the duration does not exceed the
time between impulses from the remote switch
for proper operation. 0 a 9,9 sec.
Setting this parameter to 0 will cause the Air
Shot to remain active for the duration of the
impulse from the remote switch
Minimum Air Pressure monitoring during cycle.
Setting 0.0 disables minimum air pressure
monitoring. Range 0.0-7.0 bar.
Maximum Air Pressure parameter during cycle.
Setting 0.0 disables monitoring.Range 0.0-7.0
bar
Description
MODE
Operation
Default
Set the value using
the
and
keys
Set the value using
the
and
keys
Set the value using
the
and
keys
Set the value using
the
and
keys
Min. 0
Max. 6
Set the value using
the
and
keys
Set the value using
the
and
keys
Set the value using
the
and
keys
to
10
100
1
1
0,0
2,5
7