5. DESCRIPTION OF COMPONENTS
Central GRIP Unit
The central unit of the lubrication system is composed of the following items:
a Tank, made of transparent plastic material, compatible with lubricants on the market.
a System for the regulation of the mixer air
a modular base (to add lubrication points)
an adjustable Mini-pump
two magnets for the installation on the machine tool (on iron surface)
Grip 0,5 litre (0.90pt) reservoir
6. INSTALLATION
6.1 UNPACKING
Once a suitable location has been identified for the installation, open the package and remove the equipment.
Check that the GRIP has not sustained damage during transport and storage.
The packaging material does not require any special disposal precautions, not being in any way dangerous or
polluting.
6.2 MOUNTING THE GRIP
Provide adequate space for the installation, leaving a minimum room of 100 mm around the panel. Mount the
GRIP at shoulder height to avoid unnatural posture or the possibility of sustaining impacts. Do not install the
GRIP in particularly aggressive or explosive/flammable environments or on components subject to vibration.
To install GRIP use the magnet at the base of the pump. For vertical installation dismount the magnet at base of
the pump and replace it with the and mounting bracket you find in the package (1). On the long side of the
bracket fix the magnet it was at the base and the second magnet you find in the package. (see fig. A)
NOTE: The surface where to place the magnet must be clean and flat. Be sure that the magnet
adhere on iron surface. (Do not install on machine with strong vibrations or hard movements.)
3
Fig. A –Magnet installation on mounting bracket
1