9. MAINTENANCE PROCEDURE

The pump has been designed and constructed so as to reduce maintenance to a minimum.
To simplify maintenance it is recommended that the equipment be mounted in an easily reached location (see paragraph 7.2).
Periodically check the tubing connections for leaks. Always maintain the equipment in a clean condition in order that any leaks
will be immediately evident.
When necessary replace the oil filling filter P/N 3130139.
Periodically empty the pressure regulator condensate trap by rotating the small red valve located at its base.
The machine does not require any special tools for carrying out checks and/or maintenance tasks. It is recommended that
suitable tools and personal protection clothing (gloves) are used in accordance with Legislative Decree 81/2008 (Safety at Work
legislation), and that they are in good condition in order to avoid injury to persons and damage to the machine.
Ensure that electrical, pneumatic and hydraulic supplies are disconnected before undertaking any maintenance tasks.

10. DISPOSAL

During the maintenance of the machine, or in the event of its being scrapped, do not discard polluting components in the
environment. Refer to local regulations for their correct disposal. At the time of final disposal of the machine it is necessary to
destroy the identification plate and all other documentation.

11. ORDERING INFORMATION

VERSIONS
N° of Dosers
1
2
3
4
5
6
7
8
ACCESSORIES
PART NUMBER
3044335
3130139
3155148
3155149
1524408
3103115C
3233193
3233191
3233188
5717300
5717301
1639111
1639112
1639115
3194003
3133283
VIP4Air - 24 V dc
3135064
3135055
3135067
3135070
3135073
3135076
3135079
3135082
DESCRIPTION
Tank complete
Filter, filling, oil
Solenoid valve 24 V dc
Solenoid valve 110 V ac
Mixer base with flow control
Mini-pump, pneumatic, complete with set of washers + 2 screws 14067
3
Washer for 7 mm
3
Washer for 15 mm
3
Washer for 30 mm
Tube, flexible Ø4
Tube, flexible Ø6
Box, connection, power supply 24 V dc
Box, connection, power supply 110 V ac
Connector + connection cable (2 m)
Connector
Kit for 3103115 – 3103116 mini-pumps
VIP4Air - 110 V ac
3135065
3135056
3135068
3135071
3135074
3135077
3135080
3135083
9