15. OPERATING HAZARDS

Compliance with the essential safety requirements and the provisions specified in the machine directive was checked by
filling out prepared check lists that are contained in the technical file.
Two types of lists were used:
• Risk assessment (UNI EN ISO 14121-1).
• Compliance with the essential safety requirements Machine Directive –EC 06/42).
The risks that were not completely eliminated, but considered acceptable, are specified below:
• During maintenance, sprays of oil at low pressure are possible (for this purpose, suitable PPE must be worn during
maintenance activities).
• Electrocution: This can only occur in the case of serious user incompetence, but the user must be qualified.
• Unsuitable postures: The correct dimensions and installation methods are described in this manual.
• Use of unsuitable lubricant: The specifications of the lubricant are indicated both on the unit as well as in this User and
maintenance manual (in the case of doubt, contact the Dropsa S.p.A technical office.).
Lubricants with abrasive additives.
Lubricants with silicone additives.
Petrol – solvents – inflammable liquids.
Corrosive products.
Water.
Food substances.
FLUIDS THAT ARE NOT PERMITTED
FLUIDS
Wear of internal components.
Seizure.
Fire – explosion – damage to the gaskets.
Corrosion - damage to people.
Unit oxidation.
They would be contaminated.
RISKS