Drummond 56599 Panduan Pemilik & Petunjuk Keselamatan - Halaman 3
Jelajahi secara online atau unduh pdf Panduan Pemilik & Petunjuk Keselamatan untuk Pompa Air Drummond 56599. Drummond 56599 12 halaman. 1/4 hp submersible utility pump with fully automatic on/off operation
26. Periodically inspect the pump and system
components to ensure the pump suction screen
is free of mud, sand, and debris. Disconnect the
pump from the power supply before inspecting.
27. Follow all local electrical and safety codes, along
with the National Electrical Code (NEC). In
addition, all Occupational Safety and Health
Administration (OSHA) guidelines must be followed.
28. The motor of this pump has a thermal protector that
will trip if the motor becomes too hot. The protector
will reset itself once the motor cools down and an
acceptable temperature has been reached. The
pump may start unexpectedly if it is plugged in.
29. Before using the pump, check the hose for holes or
excess wear, which could cause leaks, and ensure
the hose is not kinked or making sharp angles. A
straight hose allows the pump to move the greatest
amount of water quickly, and also check that all
hose connections are tight to minimize leaks.
30. This pump is made of high-strength,
corrosion-resistant materials. It will provide trouble-
free service for a long time when properly installed,
maintained, and used. However, inadequate
electrical power to the pump, dirt, or debris may
cause the pump to fail. Please carefully read
the manual and follow the instructions regarding
common pump problems and remedies.
Fluid Type
The Pump is designed for use with water at a maximum temperature of 95° F (35°C) and minimum of 32° F (0° C).
Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products.
Item 56599
For technical questions, please call 1-888-866-5797.
31. This pump is fully automatic in operation. If
the water level is over 2 in., the water detector
senses water. Then the control system built in
the pump automatically starts the pump and the
pump continues to run until water is pumped down
to 3/4 in. deep, and then it stops. If the water
level is not over 2 in., the pump will not start.
32. Electric shock hazard! GFCI receptacles will provide
protection against line to ground faults only. The
ground fault receptacle does NOT limit the magnitude
of fault current and will NOT prevent an electrical
shock. Replace damaged cord immediately.
33. Risk of electric shock. This pump has NOT
been tested for use in marine areas.
34. Do not move, position, retrieve, or carry pump
using the power cord or the discharge hose,
damage to the pump or power cord may occur.
Use the handle supplied on the pump or attach a
string to the strainer to position as instructed.
35. The warnings, precautions, and instructions
discussed in this instruction manual cannot cover all
possible conditions and situations that may occur.
It must be understood by the operator that
common sense and caution are factors
which cannot be built into this product, but
must be supplied by the operator.
Page 3