DRYDEN AQUA DA-GEN 500 Panduan Servis - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Servis untuk Sistem Penyaringan Air DRYDEN AQUA DA-GEN 500. DRYDEN AQUA DA-GEN 500 3 halaman.

2.1
2.2 Parameters related to external devices:
Parameter 4, 8 and 9 – Configures auxiliary disinfection dosing pump on Relay AUX 2.
Parameter 10 – Configures the pH management (only acid dosing on Relay pH, acid and base dosing on Relay pH and AUX 1, only base
dosing on Relay AUX 1).
Parameter 14 and 15 – Activates the temperature related functionalities.
Range
0 Ion pol 1 time
0...999
RW
Val: 10
000A
1 Ion pol 2 time
0...999
RW
Val: 10
000A
2 Ion dead time
0-5
RW
Val: 0
000A
3 Flow mode select
RW
Val: 0
000A
0-1
4 Hydrolisis mode
RW
Val: 0
000A
0-1-2
5 Hidro pol 1 time
0...999
RW
Val: 30
001E
6 Hidro pol 2 time
0...999
RW
Val: 30
001E
7 Hidro dead time
0...5
RW
Val: 1
0001
8 Redox/Cl relay wait time
RW
Val: 0
0000
0...999
9 Redox/Cl relay work time
RW
Val: 0
0000
0...999
10 pH setpoint mode
RW
Val: 0
0000
0-1-2
14 Show/use temperature
RW
Val: 1
0001
0-1
15 Heating
RW
Val: 1
0001
0-1
3.1
2. SERVICE SETTINGS
Standard
Dimension
Description
factory value
Minutes
10
Ionisation (Cu/Ag) positive polarity (only products including ionizer).
Minutes
10
Ionisation (Cu/Ag) positive polarity (only products including ionizer).
Minutes
0
Dead time ionizer.
0 - FL1 Lack of water flow - It turns off only the cell.
1 - FL1 Lack of water flow - It turns off everything (cells, pumps, ionization...)
2 - FL2 Lack of water flow - It turns off only the cell.
1
3 - FL2 Lack of water flow - It turns off everything (cells, pumps, ionization...)
4 - FL1 & FL2 If both detected no water flow, it turns off everything (cells, pumps, ionization...)
Configures stops/starts of the electrolysis/hydrolysis cell and auxiliary disinfection pump on
Relay AUX 2 according to redoX reading.
0 - Without redoX/CL
is controlled by redoX/free chlorine CL
1
1 - With redoX/CL
disinfection dosing pump is activated if redoX falls more than 2% lower than set point.
2 - With redoX/CL
chlorine dosing pumps are controlled via time delays of parameters 8 and 9.
Minutes
300
Polarity 1 of electrolysis/hydrolysis cell.
Minutes
300
Polarity 2 of electrolysis/hydrolysis cell.
Minutes
1
Dead time electrolysis/hydrolysis cell.
Corresponds to auxiliary disinfection dosing pump if parameter 4 is set to value 2.
Minutes
1
Time delay of auxiliary disinfection pump on Relay AUX 2.
Corresponds to auxiliary disinfection dosing pump if parameter 4 is set to value 2.
Minutes
60
Maximum dosing time of auxiliary disinfection pump on Relay AUX 2.
0 - Acid and base are activated – controls 2 relays: relay pH and relay AUX 1.
1 - Only controls Acid: Relay pH.
1
2 - Only controls Base: Relay pH.
0 - Temperature is not shown.
0
1 - Temperature is shown in display if the temperature probe is connected.
0 - The Temperature probe does not control the heating relay. The relay AUX4 can be used as
"auxilary relay".
0
1 - The Temperature probe controls the heating relay.
2 - Maximum and minimum temperature controls the heating connected to Relay AUX 4,
allowing the cooling and heating of the pool.
3. TYPE OF PUMP
3.2
3.2 With the plus/minus keys, select
the pump type connected to the system
(the default is a standard pump type).
The configuration allows the control
of two different variable speed pumps
(Variable Speed A or Variable Speed B).
In case of a variable speed pump (A or
B), establish the speed when the cover
is closed, when the pool heating is
connected and/or it controls a backwash
filter (Besgo).
(electrolysis/hydrolysis cell is always ON) - Auxiliary disinfection pump
2
.
2
(redoX/free Cl set point stops/starts electrolysis/hydrolysis cell) - Auxiliary
2
(redoX set point stops/starts electrolysis/hydrolysis cell) - Auxiliary free
2
3.3
3.3 Variable Speed Pump A (Hayward
During the filtration periods, the corresponding relay
closes. The filtration pump opens and closes contacts
depending on the speed:
Common + 1 – Slow speed
Common + 1 + 2 – Medium speed
Common + 1 + 2 + 3 – Fast speed
Variable Speed Pump A B (Speck
the filtration periods, the corresponding relay closes.
It's necessary to connect a wire from the filtration relay
to the common. The filtration pump opens and closes
contacts depending on the speed:
Common + 1 – Slow speed
Common + 2 – Medium speed
Common + 3 – Fast speed
2.2
®
or similar):
®
or similar): During