DRYDEN AQUA DA-GEN Panduan Pengguna - Halaman 5
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Inverter DRYDEN AQUA DA-GEN. DRYDEN AQUA DA-GEN 9 halaman.
Juga untuk DRYDEN AQUA DA-GEN: Panduan Pengguna (13 halaman)
3.1
3.1 Hydrolysis/Electrolysis:
3.2 Level:
Programming of hydrolysis
Hydrolysis - Desired
disinfection production (%).
or electrolysis functions
(according to model).
4.1
Optional pH control
Metering and control of
the pH of the water
The redox value advises us of the oxidation/reduction potential and is used to determine the level of water sterilization. The parameters or setpoints are the minimum/
maximum accepted redox levels before the titanium cell is connected/disconnected. Adjusting the ideal redox level (setpoint) is the last step in the system start up
sequence. Remember to check the redox set-point every 2-3 month and/or if the water parameters change (pH/temperature/conductivity).
Optional redoX control
Metering and control of the
redox as check value of the free
chlorine.
3. HYDROLYSE / ELEKTROLYSE
3.2
3.3 Salinity:
Measuring gr/l
of salt in water.
See section
9-Salinity.
4. MEASURES / SETPOINTS
4.2
4.1 MEASURES / pH Calibration
4.4
pH
4.2 MEASURES / redox Calibration
4.9
redoX
3.3
3.4
3.4 Boost: Filtration during 24h
at max intensity. Automatic return
to programmed filtration mode.
During the boost period the redoX
control can be deactivated.
4.3
4.1 Measures: Adjustment of setpoints and measuring probes.
4.2 Setpoints for each measurement.
4.3 Setpoints settings: Ideal setpoints for each of the parameters.
The default values are:
pH: 7.0-7.4; redox: 600 - 800 mV; free chlorine: 0.1- 0.5 ppm;
conductivity: ~ 2000
4.5
4.7
4.10
4.12
2
3.5
3.5 Mode: If the device
3.6 Cover: connection
of automatic cover.
has Free Chlorine and
redox probes, choose the
See section 10-Cover.
parameter that controls the
cell's chlorine generation.
4.6
4.4 Calibration of pH probe:
Recommended every month during
usage season.
4.5 Calibration with buffers (buffer
solutions pH7 / pH10 / neutral):
Follow the instructions in 7 steps
that appear in the display (screen 4.6
corresponds to step 1).
4.7 Manual calibration: Allows to adjust the
4.8
probes at 1 point (without buffers) – only
recommended to adjust small deviation in
the readings.
4.8 Without removing the probe from
the water, use the plus/minus keys to
adjust the reading so it matches with
your reference value (photometer or other
measurement).
4.9 Calibration of the redox probe:
4.11
Recommended every 2 months during
usage season.
4.10 Calibration with buffer (buffer
solution 465 mV): Follow the instructions
in 4 steps that appear in the display
(screen 4.11 corresponds to step 1).
4.13
4.12 Manual calibration: Allows to adjust
the probes at 1 point (without buffers) – only
recommended to adjust small deviation in
the readings.
4.13 Without removing the probe from the
water, use the plus/minus keys to adjust the
reading so it matches with your reference
value (photometer or other measurement).
3.6