4 Operation
NOTICE
Water pipe freeze prevention. Even if you turn OFF
space heating/cooling operation ([C.2]: Operation >
Space heating/cooling), water pipe freeze prevention –
if enabled– will remain active.
1 Go to [C.2]: Operation > Space heating/cooling.
C.2
Operation
Room
On
Space heating/cooling
On
Tank
Off
2 Set operation to On or Off.
Tank heating operation
NOTICE
Disinfection mode. Even if you turn OFF tank heating
operation ([C.3]: Operation > Tank), disinfection mode will
remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
C.3
Operation
Space heating/cooling
On
Tank
Off
2 Set operation to On or Off.
4.4

Space heating control

4.4.1

Setting the space operation mode

About space operation modes
This unit is a heating only model. The system can heat up a space,
but NOT cool down a space.
4.4.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
1
Room
2 Adjust the desired room temperature.
a
b
1
21
°C
Room
a Actual room temperature
b Desired room temperature
Operation manual
8
+
If scheduling is on after changing the desired room temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired room temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off room temperature scheduling
1 Go to [1.1]: Room > Schedule.
2 Select No.
4.4.3
To change the desired leaving water
temperature
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Only adjust the leaving water temperature settings in case
of problems.
You can use the leaving water temperature setpoint screen to read
out and adjust the desired leaving water temperature.
1 Go to [2]: Main zone or [3]: Additional zone.
2
Main zone
3
Additional zone
2 Adjust the desired leaving water temperature.
a
b
2
35
°C
Main zone
a
b
3
45
°C
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
4.5

Domestic hot water control

4.5.1

Reheat mode

In reheat mode the DHW  tank continuously heats up to the
temperature shown on the home screen (example: 50°C) when the
temperature drops below a certain value.
+
+
EHVZ04+08S18+23EA6V+9W