Dryton MiTime T720M Panduan Pemilik

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Termostat Dryton MiTime T720M. Dryton MiTime T720M 2 halaman. Mitime programmer series rf packs

Drayton
HOMEOWNER Guide
MiTime
Programmer Series
TM
RF Packs
Single Channel: MiTime T710R
Dual Channel: MiTime T720R, T720M
What is a programmer?
Multi Channel: MiTime T740R, T740M
... an explanation for householders
Programmers allow you to set 'On' and 'Off' time
periods. Some models switch the central heating and
domestic hot water on and off at the same time, while
others allow the domestic hot water and heating to
come on and go off at different times.
Set the 'On' and 'Off' time periods to suit your own
lifestyle. On some programmers you must also set
whether you want the heating and hot water to run
MiSta t
MiT ime
continuously, run under the chosen 'On' and 'Off'
heating periods, or be permanently off.
The time on the programmer must be correct. Some
Invensys
types have to be adjusted in spring and autumn at the
changes between Greenwich Mean Time and British
Customer Service Tel: 0845 130 5522
Summer Time.
Customer Service Fax: 0845 130 0622
You may be able to temporarily adjust the heating
Technical Helpline: 0845 130 7722
programme, for example, 'Override', 'Advance' or
Website: www.draytoncontrols.co.uk
'Boost'. These are explained in the manufacturer's
instructions.
l
@DraytonControls
The heating will not work if the room thermostat has
x
/DraytonControls
switched the heating off. Also, if you have a hot-water
cylinder, the water heating
EU Design Regs:- 002180638-1/2/3
will not work if the cylinder
User Guide 06490193001 Iss F
thermostat detects that the
hot water has reached the
correct temperature.
HOMEOWNER Guide
What is a room thermostat?
What is a cylinder thermostat?
... an explanation for householders
... an explanation for householders
A room thermostat simply switches the heating
A cylinder thermostat switches on and off the heat
system on and off as necessary. It works by sensing
supply from the boiler to the hot-water cylinder. It
the air temperature, switching on the heating when
works by sensing the temperature of the water inside
the air temperature falls below the thermostat setting,
the cylinder, switching on the water heating when the
and switching it off once this set temperature has
temperature falls below the thermostat setting, and
been reached.
switching it off once this set temperature has been
reached.
Turning a room thermostat to a higher setting will not
make the room heat up any faster. How quickly the
Turning a cylinder thermostat to a higher setting will
room heats up depends on the design of the heating
not make the water heat up any faster. How quickly the
system, for example, the size of boiler and radiators.
water heats up depends on the design of the heating
system, for example, the size of boiler and the heat
Neither does the setting affect how quickly the room
exchanger inside the cylinder.
cools down. Turning a room thermostat to a lower
setting will result in the room being controlled at a
The water heating will not work if a time switch or
lower temperature, and saves energy.
programmer has switched it off. And the cylinder
thermostat will not always switch the boiler off,
The heating system will not work if a time switch or
because the boiler sometimes needs to heat the
programmer has switched it off.
radiators.
The way to set and use your room thermostat is to
find the lowest temperature setting that you are
Cylinder thermostats are usually fitted between one
comfortable with, and then leave it alone to do its job.
quarter and one third of the way up the cylinder. The
The best way to do this is to set the room thermostat
cylinder thermostat will have a temperature scale
to a low temperature – say 18ºC – and then turn it up
marked on it, and it should be set at between 60C and
by one degree each day until you are comfortable
65C, then left to do its job. This temperature is high
with the temperature. You won't have to adjust the
enough to kill off harmful bacteria in the water, but
thermostat further. Any adjustment above this setting
raising the temperature of the stored hot water any
will waste energy and cost you more money.
higher will result in wasted energy and increase the
risk of scalding.
If your heating system is a boiler with radiators, there
will usually be only one room thermostat to control the
If you have a boiler control thermostat, it should
whole house. But you can have different temperatures
always be set to a higher temperature than that of the
in individual rooms by installing thermostatic radiator
cylinder thermostat. In most boilers, a single boiler
valves (TRVs) on individual radiators. If you don't
thermostat controls the temperature of water sent
have TRVs, you should choose a temperature that is
to both the cylinder and radiators, although in some
reasonable for the whole house. If you do have TRVs,
there are two separate boiler thermostats.
you can choose a slightly higher setting to make sure
that even the coldest room is comfortable, then prevent
any overheating in other rooms by adjusting the TRVs.
Room thermostats need a free flow of air to sense
the temperature, so they must not be covered by
curtains or blocked by furniture. Nearby electric
fires, televisions, wall or table lamps may prevent the
thermostat from working properly.
6444 Invensys MiSeries RF Channel USER 06490193001 IssF.indd 1
Step 1: Keys and Display - MiTime
RF Packs: T710R, T720R, T720M, T740R, T 740M
MiStat
MiTi me
Select key: Press to select highlighted
options, and to open and save editor screens
Step 2: Home Screens
Single Channel: MiTime T710R
Press Select ( ) to change mode
Link to Settings
See further details in Step 6.
Temp: describes the current status
of the zone temperature, e.g.
Temperature in zone is 21.0C and the
setpoint is 21.5C
Link to modify the zone temperature.
Now: describes the current status,
e.g. programme is On until 12:00 am.
Link to Programme timetable - see
further details in Step 4.
Current mode: Auto
Options: see table in Step 3.
Date
: Indicates an RF transmission issue or
Service warning.
: Indicates that holiday is enabled
Home key: Press to go back
to the home screen at any
time
Back key: Press to return to
the previous screen
MiTime
This icon used
throughout these
instructions refers
to this button
Dual Channel: MiTime T720R, T720M
Press Select ( ) to view or edit zone
Zone = Heating
Current status: the programme is On
until 12:00 am
Link to zone details, see Step 3.
Zone = Hot Water
Current status: the programme is
Off until 12:00 am
Link to zone details, see Step 3.
Link to Settings
See further details in Step 6.
Note:
See help in product menu for quick
Home screen, depending on
button description.
model - see Step 2
Time
+hr key: Press from the
home or zone details
screens to add up to 3 hours
to the current period
Advance key: Press from
the home or zone details
screens to advance to the
next on or off period
Help text to prompt for
next action. It relates to the
highlighted line
LED: Illuminates when any
zone is scheduled to be ON
Arrow keys: Press to move
the highlight on screen, and
to change field values
Step 3: Zone Details
Multi Channel: MiTime T740R, T740M
Zone = Heating
Press Select ( ) to view or edit zone
Zone = Heating
Current status: the programme is On
until 12:00 am
Link to zone details, see Step 3.
Temp: describes the current status of the
zone temperature, e.g. Temperature in
zone is 21.0C and the setpoint is 21.5C.
Link to modify the zone temperature.
Zone = Zone 3
Current status: the programme is Always Off
Now: describes the current status, e.g. programme
Link to zone details, see Step 3.
is On until 12:00 am. Link to Programme timetable
- see further details in Step 4.
Zone = Hot Water
Current status: the programme is Off until
12:00 am. Link to zone details, see Step 3.
Mode:
Link to Settings
Auto
See further details in Step 6.
Always Off
Always On
All Day
(first on / last
off)
(not Single Channel)
Current mode: Auto
Options: see table below.
Link to Programme timetable
See further detail in Step 4.
Press Select ( ) to change mode
Description:
The programmer will control the
ON & OFF times in line with the
programmed timetable
The selected zone will be OFF
The selected zone will be ON
The programme will control the
ON & OFF times in line with the
programmed timetable, but using
only the first ON event and the last
OFF event - it will remain ON in
between these two periods.
27/09/2013 09:19