Daikin FTKS60FVMV Panduan Servis - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Servis untuk Penangan Udara Daikin FTKS60FVMV. Daikin FTKS60FVMV 20 halaman. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Juga untuk Daikin FTKS60FVMV: Panduan Servis (20 halaman)

Daikin FTKS60FVMV Panduan Servis

Vertical Blade ASSYs

5. Vertical Blade ASSYs
Warning
Step
1. For auto-swing (right and
left) models
1
Release the right and
left shafts.
2
Unfasten the 3 hooks
for each set of vertical
blade ASSY (9 hooks).
3
Pull the vertical blade
ASSYs to the right and
remove them.
6
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Vertical blade ASSY
Interlock rod
(R21153)
Hook
(R2768)
(R6706)
Si041254EE
Points
Some models have fan
guards. Remove the fan
guards beforehand.
The unit has 3 sets of
vertical blade ASSYs linked
to one another with interlock
rods.
Removal Procedure