Daitron PFS300A-30 Buku Petunjuk - Halaman 4
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Catu Daya Daitron PFS300A-30. Daitron PFS300A-30 7 halaman. Pfs300a series switching power supply
2-8
Remote On/Off
・
This unit comes with an integral on/off circuit, see wiring
diagram below.
・
Unit DC output is disabled when control voltage is applied
to RC terminal in reference to –V terminal.
・
If SW is open or control voltage E is: 0 < E < 4.5V then unit
output is enabled.
・
If SW is closed and control voltage E is: 4.5VDC < E
< 6.5VDC then output is disabled, and no need for current
limiting resistor R.
・
If SW is closed and control voltage E is: 6.5VDC < E
< 24.5VDC, then current limiting resistor R must be =
(E – (1.1 +1000x0.005))/0.005. For example if E = 24VDC,
R = (24-(1.1+5))/0.005 = 3.5kΩ
2-9
Series Operation
・ This Daitron power supply unit is configurable in series
with another Daitron power supply (if it too is configurable
in Series) in order to increase DC voltage or to provide
both "+" and "–" DC voltage.
・ In these configurations the MAXIMUM current delivered to
the Load is limited to the maximum allowable from the
power supply with the lowest current rating.
・ To increase VDC (PS1 + PS2) see configuration (1) below.
Example: If PS1 and PS2 are both 12VDC/30W each, then
configuration (1) will provide 24VDC/30W
・ To provide both "+" and "–" DC voltage to a load see
configuration (2) below. Example: If PS1 and PS2 are both
12VDC/30W each, then configuration (2) will provide +12VDC
to Load1 and -12VDC to Load2, with a maximum total wattage
of 30W for both loads combined.
2-10
Parallel Operation
・
This power supply can not be configured in parallel with
another power supply.
負
2-11
Ripple
・ Maximum ripple voltage is measured using JEITA
measurement method prescribed in RC-9131C.
・ If ripple noise becomes excessive due to line length,
connect an electrolytic capacitor(47μF) and film capacitor
(0.1μF) at load side as shown.
The maximum ripple voltage in the standard specification is a value
measured using the specified measuring circuit in the anechoic
chamber under the JEITA measuring method (See the drawing).
When the load line is long, the ripple on the load edge may become
large unless a capacitor, such as an electrolytic capacitor or a film
capacitor is connected. The output ripple cannot be measured
accurately if the ground lead of the oscilloscope is too long.
Ta=25C Vin=100Vac, Typical value at the rated output
10001-005WE-00