INSTALLATION INSTRUCTIONS
Each WLS904 motion detector should be located so that it provides
optimal coverage of the intended area. Refer to Changing Motion Detector
Lenses below for information on the four lenses available for the WLS904
Motion Detector. When locating motion detectors, observe the following:
• For the Wall-to-Wall, Corridor and Curtain Lenses, the Mounting Height
should be 6-10 ft./ 2-3 m from the floor. The nominal mounting height is
7.5 ft./ 2.3 m.
• For the Pet Alley Lens only, the Mounting Height should be 4-5 ft./1.2-1.5m
from the floor.
• Do not aim the detector at reflective surfaces such as mirrors or
windows. This may distort the coverage pattern or reflect sunlight
directly onto the detector. Avoid locations where the detector may be
exposed to direct or reflected sunlight.
• Avoid locations that are subject to direct air flow, such as near an air duct outlet.
• Do not locate the detector near sources of steam or oil vapor, such as
a stove or fryer.
• Do not obscure the Detector's coverage pattern with large objects within
the detection area. If you can't see the detector, it can't see you.
• For indoor use only
• Dead zone 6"/15 cm
NOTE: No detector should be mounted without first performing a
module placement test to determine that it is in range of the
wireless receiver. See the Placement Test instructions in the
Instruction Sheet for your receiver, or in the installation manual for
your system.
When a location has been determined,
remove the plastic from the mounting
holes and locate the backplate on the
wall and mark screw locations. It is
suggested that wall anchors be used for
all screw locations. Secure the backplate
to the wall, and then secure the enrolled
Detector to its backplate.
Please refer to the System Installation Manual for information on
limitations regarding product use and function and information
on the limitations as to liability of the manufacturer.
• W A R N I N G •
ENSURE PROPER
ORIENTATION OF
BACKPLATE.
MOUNTING HOLE
KNOCKOUTS
CORNER MOUNTING
KNOCKOUTS
Motion Detector Backplate