DSC Power Series Manual - Halaman 2
Jelajahi secara online atau unduh pdf Manual untuk Layar sentuh DSC Power Series. DSC Power Series 18 halaman. Neo image sensor
Juga untuk DSC Power Series: Panduan Referensi (2 halaman), Panduan Referensi Cepat (2 halaman), Panduan Instalasi (14 halaman), Petunjuk Instalasi (2 halaman), Panduan Cepat (4 halaman), Panduan Petunjuk Instalasi (11 halaman)
DSC Power Series PC1616 PC1832 PC1864 System Manual
Maintenance
With normal use, the system requires minimum maintenance. Note the following points:
Do not wash the security equipment with a wet cloth. Light dusting with a slightly moistened cloth
should remove normal accumulations of dust.
For other system devices such as smoke detectors, passive infrared, ultrasonic or microwave
motion detectors or glassbreak detectors, consult the manufacturer's literature for testing and
maintenance instructions.
Arm & Disarm the System
Arming (Turning On/Setting)
Close all sensors (i.e. stop motion and close doors). The Ready (checkmark) indicator should be on.
To arm, press and hold the Away key for two seconds and/or enter your Access Code, or press [*][0] to
Quick Arm. During the setting state (exit delay active) the Armed (lock) and Ready (checkmark) indicators
will turn on, and the keypad will sound one beep per second. To cancel the arming sequence, enter your
access code.
Away Arming (Turned On/Set)
When the exit delay is completed, the alarm system is armed/set and this is indicated on the keypad as
follows: the Ready (checkmark) indicator will turn off, the Armed indicator will remain on and the keypad
will stop sounding.
Quick Exit
If the system is armed and you need to exit, use the Quick Exit function to avoid disarming and rearming
the system. Press and hold the [EXIT] key for two seconds or press [*][0]. You now have two minutes to
leave the premises through your exit door. When the door is closed again, the remaining exit time is
canceled.
Bell/Siren Sounds After Away Arming
Audible Exit Fault
In an attempt to reduce false alarms, the Audible Exit Fault is designed to notify you of an improper exit
when arming the system in the Away mode. In the event that you fail to exit the premises during the
allotted exit delay period, or if you do not securely close the Exit/Entry door, the system will notify you
https://alpha.adt.com/help/61[11/12/2018 9:40:17 PM]