DSE Gencomm DSE7300 Series Panduan Memulai Cepat - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Pengontrol DSE Gencomm DSE7300 Series. DSE Gencomm DSE7300 Series 4 halaman. Control keys and remote control outputs

DSE Gencomm DSE7300 Series Panduan Memulai Cepat
• SYSTEM CONTROL KEYS
Not all functions are supported by all modules. The Gencomm protocol includes a method of reading the list of
supported functions from the connected controller. This is detailed in the full Gencomm Protocol Document, available
from
Function
System control function
code
0
Select Stop mode
1
Select Auto mode
2
Select Manual mode
3
Select Test on load mode
4
Select Auto with manual restore mode
5
Start engine if in manual or test modes
6
Mute alarm
7
Reset alarms
8
Transfer to generator
9
Transfer to mains
10
Reset mains failure
11
Close Bus (Bus Tie Controller)
12
Open Bus (Bus Tie Controller)
13
Toggle Bus Open/Closed (Bus Tie Controller)
14
Scroll through mode selections
(mode button on 330/331/334/335)
15
Enable selected mode
(scroll button on 330/331/334/335)
16-31
Reserved
32
Telemetry start if in auto mode
33
Cancel telemetry start in auto mode
34
Reset alarms
35
Clear telemetry alarm flag
36
Lock the user controls
37
Unlock the user controls
38
Reset the maintenance alarm 1 due times
39
MSC alarm inhibit on
40
MSC alarm inhibit off
41
Reset the maintenance alarm 2 due times
42
Reset the maintenance alarm 3 due times
43
8721 Display unit registered/alive (pre-v6)
8610 Remote start off load (sync lock)
44
8711 Display unit registered/alive (pre-v6)
8610 Remote start off load cancel (sync lock)
45
8716 Display unit registered/alive (pre-v6)
8610 MSC alarm inhibit on and switch to manual mode (sync
lock)
46
Start data logging (temporarily overrides the module state)
47
Stop data logging (temporarily overrides the module state)
48
Erase all data log files internal to the module (NOT on USB)
49
Force USB drive to stop logging, ready to eject
50
Control Processor Reset Lockout Enable (88xx/84xx only) – sent
by the display processor to the control processor to signal when
the control processor should lockout the reset signal from the
display processor
51
8721 Display unit registered/alive (v6 & later)
52
8711 Display unit registered/alive (v6 & later)
53
8716 Display unit registered/alive (v6 & later)
056-051 Gencomm Control Keys Issue 3 – A.D.Manton
upon request.
System control
Ones compliment
key
of control key
(decimal)
(65535-control
35700
35701
35702
35703
35704
35705
35706
35707
35708
35709
35710
35711
35712
35713
35714
35715
35732
35733
35734
35735
35736
35737
35738
35739
35740
35741
35742
35743
35744
35745
35746
35747
35748
35749
35750
35751
35752
35753
key)
29835
29834
29833
29832
29831
29830
29829
29828
29827
29826
29825
29824
29823
29822
29821
29820
29803
29802
29801
29800
29799
29798
29797
29796
29795
29794
29793
29792
65535
29791
65535
29790
65535
29789
29788
29787
29786
29785
29784
29783
29782