DSE SD-5 Series Panduan Pengguna - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kamera Digital DSE SD-5 Series. DSE SD-5 Series 15 halaman.

DSE SD-5 Series Panduan Pengguna
USER MANUAL
SPEED DOME CAMERAS SD-xxx-5
Page:4
standard)
and
the
(2400,4800,9600 baud)
Each camera must have a different address from the
others in order to be identified along the BUS.
These 3 parameters: Protocol, Baud rate and Address
are set in the camera OSD menu.
Set the factory log data in
the operating unit
The cameras support the standard PELCO P and PELCO
D command protocols, which are supported by most
consoles and DVRs. Protocol recognition is automatic.
The communication parameters of the speed (baud
rate) and address of the camera are set in the OSD
menu of the camera. To access the menu, at least
initially, your control unit (DVR or console) must be set
to the factory parameters of the camera, which are:
The factory setting is:
BAUD RATE: 2400 BPS
ADDRESS 1
The
communication
data
superimposed on the image
Set the final protocol data of
the camera
Once the control center has been set to the PelcoD /
2400 / ID1 communication parameters, it is possible to
set the final ID and speed of the camera. In fact, if you
have only one PTZ camera, you can keep the Factory
ID, but if there are more than one, you have to assign
them different addresses.
Proceed as follows:
1 - Call up PRESET 95 to open the OSD menu
same
transmission
speed
set
in
the
camera
2 - Move to DOME with the up and down arrows, then
press the right arrow to enter the dome menu
is
3 - Enter the COMM menu with the arrows on the right
4 - In order to modify the communication parameters,
the CHECKID must be written identical to the DEVICE
ID. This procedure is to avoid that the communication
parameters are modified in an unconscious way. Move
to CHECKID and press the right arrow to then modify
the value with the up and down arrows until it is equal
to the DEVICE ID
WWW.DSE.EU