1.04 Wiring Terminals

Terminal
Trigger
0Vdc -
12Vdc +
Line In
Earth
Line In
Set
Set
1.05 Wiring Diagram AD1200 to ST6100, ST6500 & ST6600 and other Panels
ST6100 & ST6600
+ 12V
- 12V
INP
SET
SET
LINE
LINE
Note:
If you are not using the S+ on the ST6100 & ST6600, you can enter engineer programming in
those control panels and change the Switch Positive to 0V. If a secure zone is activated in the
ST6100 or ST6600 the Dialer will dial the programmed numbers. The alarm trigger must be
programmed as 12Vdc.
Enter engineering programming in the ST6100 & ST6600:
Press: 5
Press: 9 Day LED Flashing = 0V
Press: Reset
AD1200 Installer Manual, Rev. 19.06.2013
Connection
Trigger 0V or 12Vdc
Negative Supply (OV)
Positive Supply (12+)
Telephone Line In
Ground/Earth Wire
Telephone Line In
Telephone Hand Set
Telephone Hand Set
ST6000 & ST6500 & other Panels
+ 12V
- 12V
INP
SET
SET
EARTH
LINE
LINE
3
Suggested Wire Colour
Blue
Black
Red
Green
Yellow
Red
Green
Red
EARTH