Atsumi Electric IR36EXA Panduan Instalasi - Halaman 5
Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Sensor Keamanan Atsumi Electric IR36EXA. Atsumi Electric IR36EXA 8 halaman. Passive infrared detector
8
Coverage Setup
This unit allows for 360 degree coverage mounting three (3) 120 degree optical assemblies. You can adjust the mirrors either
simultaneously or independently.
1. SIMULTANEOUS SETUP
Rotate the adjusting plate to align V-shaped protrusion with the desired mounting height. In this case, coverage of 20
meters in diameter is achieved.
2. INDEPENDENT SETUP
1 Rotate the adjusting plate clockwise until V-shaped protrusion reaches "Free" position. Each mirror is then adjustable
independently.
2 Determine the rod position from the desired Mounting Height & Max. Range shown on the adjusting plate.
NOTE: Arrows and their area numbers are indicated on the label of the base unit. Each arrow is centered in each coverage
of 120 degrees and its number stands for each one of three (3) areas. The same numbers are also marked on the
adjusting plate of the sensor unit to match each other when fixed together.
In order to rotate the adjusting plate counterclockwise from "Free" position, all rods must be placed at the center
ends.
9
Walk Test
1. Make sure the dip switch 1 is ON.
2. Wait for 1 minute after power is turned on (LED blinks for warm-up).
3. Conduct walk test across the coverage pattern. Observe the Alarm LED while walking across the coverage.
It will light as you enter the detection area.
4. In case Alarm LED does not light, adjust the coverage and pulse count settings.
Repeat the above steps until Alarm LED lights.
Adjusting plate
Arrow and area number
Rod
Area number
5
V-shaped protrusion
Align the rod to C position
for 4 meter height and 8
meter coverage.