DSPeaker Servo 300 Panduan Pengguna - Halaman 12

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Pembicara DSPeaker Servo 300. DSPeaker Servo 300 16 halaman. Dspeaker servo 300

DSP
 S
 300
EAKER
ERVO
2.5 ASCM Calibration
The speakers are incorporated with patent pending processor controlled Position Feedback  
measurement  and  Active Suspension Compliance Management System, ASCM. Thanks to 
the   ASCM,   the   speaker   will   not   suffer   any   common   phenomena   of   uncontrolled   low­
frequency   energy   storages,   and   will   deliver   the   fastest,   tightest   and   most   accurate   bass 
possible even to the lowest octaves in­room. The speaker has also not herited the "boxy" or 
"boomy"   sound   character   of   reflex­type   speakers,   as   the   active   suspension   with   closed 
enclosure will offer unmatched control over the entire audible bass range.
The ASCM is calibrated at the factory, which will be sufficient for years to come. However, as 
in all speaker drivers, the spring compliance of the cone will vary after extensive usage over 
the years. To compensate for this, it is adviceable to run ASCM calibration once the speaker 
has been used for about one or two years (depending on activity). Later on, the parameters 
do not vary any more, meaning ASCM  doesn't necessarily need to be calibrated again.
ASCM calibration will measure how much the suspension compliance has been altered since 
the original values, and automatically compensate for these. The settings are stored in the 
internal   memory   of   Servo   300,   where   they   will   remain   until   another   ASCM   calibration 
overwrites them. 
Before calibration, the output gain must be at 0dB, or the calibration will not begin. 
The   ASCM   calibration   is   performed   quite   like   the   Anti­Mode   calibration,   except   the 
microphone is not connected to its jack. To perform ASCM calibration, simply press and hold 
the control button. The calibration will make one sweep, but after it detects that there is no 
microphone   connected,   it   will   continue   with   different   kind   of   test   signals   (subsonic   high­
excursion excitation). The ASCM calibration will also feature restarting of the speaker, and 
remeasuring the rest position of the cone springs. It is extremely important not to touch 
the   speaker   cone   even   if   it   there   is   no   sound   nor   movement   during   the   ASCM 
calibration!  The  ASCM   calibration  is  finished  once  the  speaker   will  return  to  it's   normal 
operation state (led is green if Anti­Mode was engaged and orange if it was bypassed).
Note: The ASCM calibration does not affect on the room corrections being applied after Anti­
Mode calibration.
Rev. 1.6
21.06.2010
Page 12 (16)