ATTO Technology Celerity FC-161E Panduan Instalasi dan Pengoperasian - Halaman 8
Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pengoperasian untuk Adaptor Host ATTO Technology Celerity FC-161E. ATTO Technology Celerity FC-161E 20 halaman. Celerity fibre channel host adapters
Celerity Fibre Channel 8Gb Adapters
The ATTO Celerity 8Gb HBAs leverage two next-
generation storage technologies: PCIe 2.0
interconnect and 8-Gigabit Fibre Channel.
With 8-Gb FC speeds of up to 800 MB/sec. per
channel, 8Gb Celerity adapters support the most
demanding application requirements, including high-
definition video, rich content databases and other
high-bandwidth environments.
ATTO Celerity host adapters are an integrated family
of advanced storage connectivity solutions that are
designed to provide reliable connectivity, intelligence
and scalability.
84EN Technical specifications
• Four independent Fibre Channel ports 8-Gigabit
data transfer rates
• 1600 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: fabric, arbitrated
loop and point-to-point
• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 41
• ATTO Advanced Data Streaming (ADS™)
Technology
• Length: 6.6 inches
• Height: 3.987 inches
• Operating temperature: 0-40 ºC (32-104 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 7.8 W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
4 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
82EN Technical specifications
• Two independent Fibre Channel ports
• 1600 MB/sec. maximum throughput per channel
in full-duplex mode
• 8-Gigabit data transfer rates
• Conforms to PCI Express Low Profile form-
factor specifications
• Supports all FC topologies: fabric, arbitrated
loop and point-to-point
• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 41
• ATTO Advanced Data Streaming (ADS™)
Technology
• Length: 6.6 inches
• Height: 2.731 inches
• Operating temperature: 0-40 ºC (32-104 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 5.9W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant