DTM System SLIM 2 Instruksi Pemasangan - Halaman 2
Jelajahi secara online atau unduh pdf Instruksi Pemasangan untuk Aksesori DTM System SLIM 2. DTM System SLIM 2 4 halaman. Photocell
4. Photocell connection
Photocell cooporates with most of gate controllers available on market.
It is recommended to do electrical installation and photocell mounting by qualified person.
Connect photocell
according to Fig. 3 scheme
and description below.
Without synchronization function
4
Make sure the ZW jumper on the transmitter and
receiver are mounted.
4
Connect the power supply 12-24V AC/DC to
photocell transmitter and receiver. POWER LEDs
on the transmitter and the receiver, and RX LED on
the receiver should light up.
4
If you use the AC power supply to power the
transmitter and receiver use the same phase (with
one power supply)
4
Connect the output signal of photocell (usually NC
and C) to proper inputs on the control unit. Pay
particular attention to the type of control (NC or NO)
required in the control panel. The standard solution
for gate automation is to work with optical sensors in
the NC.
With the use of synchronization function
Using synchronization function, you can
install two pairs of photocells with the
overlapping area of t he optical range.
To use the synchronization function, you
must cut the ZW jumper in photocell transmitter and
receiver, and supply them with alternating voltage
(12-24V AC).
Connect the same wire to the terminal marked "1" on
the transmitter and the receiver of the first pair of
photocells. If swap wires only on the transmitter side
or only on the receiver side, will result in no action of
photocells. The second pair of photocells must be
powered by the same phase as the first, but wires in
the supply line of transmitter and receiver must be
swap. (the power wire connected to the terminal
marked "1" in the first pair of photocells, must be
swap with the next wire in the second pair of
photocells).
SLIM II photocell
MOUNTING INSTRUCTION
1
2
o
200
18 mm
Description:
1. splash-proof cover
2. hole for wires =7mm
Fig. 2 Distance of the mounting holes
on a scale of 1:1, with the assembly drawing.