2. MECHANICAL ASSEMBLY

2.1. Preparation of the workplace
In order to install it correctly, we must properly prepare the workplace. It is necessary to test the door
system in terms of the requirements presented below:
4
The drive mechanism requires space on the sides of the arms and assembly. Make sure that this place
is available. If there is no place, please provide it!
4
Gates, which operate heavy loads (wind) must be secured with an additional electric lock.
4
Check that the gate opens and closes freely.
Gateway parameters that affect the operation of the system:
4
Gate size: The size of the gate is a very important factor. Wind can brake the gate or cause certain stresses,
significantly increasing the amount of force required to move it.
4
Gate weight: The weight of the gate is an approximate parameter. However, the maximum permitted
weight of the door should not be exceeded. The actual weight transferred by the drive is influenced by the
type of gate, wind, and the space around the gate.
4
Temperature influence: Low external temperatures may hinder or prevent commissioning (soil changes,
etc.), while high temperatures may cause jamming of elements that fit too tightly due to thermal expansion
of the metal.
4
Service frequency / switch-on time: Drives have a maximum switch-on time of approximately 30% (18
cycles) per hour.
photocell
photocell
Fig. 2. Illustrative view of the gate automation installation.
The actuator must not work so that the piston extends or retracts to the end. A correctly set actuator makes
a movement of up to 99% of stroke when the gate is closed and to 1% when the gate is open. Failure to do so
will damage the actuator and void the warranty!
The drives are not designed for continuous operation within their maximum duty cycle (continuous
operation). The drive becomes too hot and switches off until the temperature reaches the switch-on
parameters again. The outside temperature and gate parameters are important factors that influence the
actual start-on time.
2
left actuator
junction box
external photocell
photocell
photocell
DTM System remote
CAUTION!
CAUTION!
antenna
junction box
right actuator
signal
lamp
gate controller
external photocell