Specifications
Specifications:
Type of charging station: Direct-current fast charging station
Output connector: Conforms to the CHAdeMO and SAE J1772 Combo standards
Input connector: Screw type distribution bloc, 350 MCM max . (for the phases), 3/0 max . (for the neutral)
Nominal voltage supply: Three-phase 480Y/277V (must be protected by a 100A, three-phase over-
current protection device .)
Maximum power consumption: 54kVA @ three-phase 480V
Maximum output power: 50kW @ 400V
Efficiency: 93% (or better) @ 50kW output
Power Factor: 0 .98 or better
The charging station is a non linear load . The use of a transformer having a K-factor of at least 9 is
recommended .
Integrated Protection:
• Against voltage surges
• Electric current leakages to ground
• Isolation failures between the AC input and DC output
Operating Temperature: -40°C to +50°C
Casing: Conforms to the NEMA 3R standards for exterior use
Weight at delivery: Approximately 250kg
Security standards compliance:
• UL 2002: Charging system for electric vehicles
• CSA 22 .2 No . 107 .1-01: general power supply
• TIL I-44: Requires interim certification for charging stations designed for electric vehicles of less than
600 Volts
2017 ADDÉNERGIE TECHNOLOGIES INC. ALL RIGHTS RESERVED. Information and Specifications Contained in this Document are Subject to Change, Amendments, and Additions at any Time, Without Notice
Model: SmartDC
TM
Revision: V2
Company Info: AddEnergie Technologies Inc .
Document revision number: V05-2017-04-10
©2017 AddÉnergie Technologies Inc . All Rights Reserved . This document
is protected by copyright laws of many countries and should not be
modified, reproduced or distributed without the prior written consent of
AddÉnergie Technologies .
DC
AC
4