3onedata IES6220-16P4GS-2P48-120W Panduan Instalasi Cepat - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Instalasi Cepat untuk Beralih 3onedata IES6220-16P4GS-2P48-120W. 3onedata IES6220-16P4GS-2P48-120W 4 halaman. Managed industrial ethernet switch

3onedata IES6220-16P4GS-2P48-120W Panduan Instalasi Cepat
Power input voltage: 220VAC (85~264VAC).
【Relay Connection】
The device provides 6-pin 5.08mm
pitch
input
including
2-pin
blocks on the right side. Relay terminals are a pair of
normally open contacts in device alarm relay. They are
open circuit in normal non alarm state, closed when any
alarm information occurs. Such as: it's closed when power
off, and send out alarm. The switch supports 1 channel
relay alarm information output, support DC power alarm
information or network abnormal alarm output, it can be
connected to alerting lamp, alarm buzzer, or other
switching value collecting devices for timely warning
operating staffs when alarm information occurs.
【DIP Switch Settings】
Provide 4 pins DIP switch for function settings,
where "ON" is enable valid terminal. DIP
switches definition as follows:
DIP
Definition
Operation
Set the DIP switch to ON,
Restore
power on the device again, it
1
factory
will restore to factory settings,
defaults
then turn off the DIP switch.
2
Reserved
-
Set the DIP switch to ON, the
program of this device can be
3
Upgrade
upgraded, then turn off the
DIP switch when this upgrade
completes.
4
Reserved
-
【Console Port Connection】
The device provides 1 channel procedure debugging port
based on serial port, and can conduct device CLI
command line management after connected to PC. The
interface adopts RJ45 port, the RJ45 pin definition is as
follows:
Pin No.
Definition
【Checking LED Indicator】
terminal
blocks,
The function of each LED is described in the table as
relay
terminal
below:
LED
P1/P2/PWR
ALM
RUN
Link/Act
(1-16,
G1-G4)
POE (1-8/16)
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface.
The way of logging in to device's configuration interface
via IE browser is shown as below:
Step 1
2
3
5
TXD
RXD
GND
Status
Description
Power supply is connected
ON
and running normally
Power supply is
OFF
disconnected and running
abnormally.
Power supply, port link
ON
alarm
Power supply, port link
OFF
without alarm
The device is powered on
ON
or the device is abnormal.
The device is powered off
OFF
or the device is abnormal.
Blinking
System is running well.
Ethernet port connection is
ON
active.
Blinking
Data transmitted
Ethernet port connection is
OFF
inactive.
POE port supply electricity
ON
for other devices normally
POE is disabled or
OFF
disconnected
Configure the IP addresses of computer and
the device to the same network segment, and
the network between them can be mutually
accessed.
Step 2
Enter device's IP address in the address bar of
the computer browser.
Step 3
Enter device's username and password in the
login window as shown below.
Step 4
Click "OK" button to login to the WEB interface
of the device.
Note:
The
default
IP
address
"192.168.1.254".
The default username and password of the device is
"admin".
If the username or password is lost, user can restore
it to factory settings via device DIP switch or
management software; all modified configurations
will be cleared after restoring to factory settings, so
please backup configuration file in advance.
Please
refer
to
user
manual
configuration method of logging in to WEB
interface and other configurations about network
management function.
【Specification】
of
the
device
is
for
specific