Comunello GCU00BS1H0G00 Instalasi dan Panduan Pengguna - Halaman 4
Jelajahi secara online atau unduh pdf Instalasi dan Panduan Pengguna untuk Unit Kontrol Comunello GCU00BS1H0G00. Comunello GCU00BS1H0G00 14 halaman.

2 WIRES CONNECTION TABLE:
TAB.01
NO.
DESCRIPTION
1
Power supply
6A
Motor power supply
2
Flashing light
4A, 5A
TX photocell
4B, 5B
RX photocell
6
Key selecton
3
Antenna
The table refers to the example of wiring shown in the FORT model manual for sliding motors.
NOTE: If the cables are of a different length than those shown in the table, the section of the cables must be determined based on the actual absorption of the
connected devices.
The requirements are reported in the EN 50575: 2014 standard:
With the publication of the standard EN 50575, in the list of harmonized standards for Regulation CPR 305/2011, Com. 2016 / C 209/03, also electric cables,
already subject to CE marking for the Low Voltage Directive 2014/35 / EU, must be CE marked also under the CPR Regulation.
In the eventualities of connections with devices connected in parallel on the same power supply line, the sizing of the cables shown in Table 1 must be re-evaluated
on the basis of the absorptions and the actual distances.
3 TECHNICAL SPECIFICATIONS
Power supply:
Flashing light output:
Motor output:
Photocells power supply:
LV safeties and controls:
Working temperature:
Radio receiver:
Transmitters:
Max TX codes stored in memory:
Board dimension:
Fuse 1 :
Fuse 2:
CABLE
LENGTH from 1m to 20m
3G x 1,5 mm2
4G x 1,5 mm2
EN standard 50575,
in the list of harmoni-
2 x 0.5 mm2
zed rules for the Regu-
2 x 0.5 mm2
lation CPR 305/2011,
Com.2016/C 209/03
4 x 0.5 mm2
3 x 0.5 mm2
RG58
230 V~ 50Hz 1600W max.
24 V~ 4W max.
230 V~ 500 W max.
24 V~ 5 W max.
24 V DC
-20 ÷ 55 °C
433 Mhz
18 Bit or Rolling Code
120 (CODE PP or CODE PED/2°CH)
100 x 105 mm.
T 6.3A L 250 V (Delayed fuse)
T 100mA L250 V (Delayed fuse)
LENGTH from 20m to 50m
3G x 2,5 mm2
4G x 2,5 mm2
2 x 1.0 mm2
2 x 1.0 mm2
4 x 1.0 mm2
3 x 1.0 mm2
Max. 20 m
COMUNELLO ®Copyright 2019 - All rights reserved
19