Pin No.
1
2
Pin Definition
TX
RX
【Communication Interface Connection】
100M M12 Interface
Provide 10/100Base-T(X) interface, the interface
type is M12 D-Coded 4-Pin slot (female). The
definitions of M12 pin are as follows:
Pin No.
Pin Definition
Description
1
TX+
Positive send data of 100M
Ethernet
2
RX+
Positive receive data of
100M Ethernet
3
TX-
Negative send data of 100M
Ethernet
4
RX-
Negative receive data of
100M Ethernet
Gigabit M12 interface
This device provides 10/100/1000Base-T(X)
interfaces, the interface type is M12 X-Coded
8-Pin slot (female). The definitions of M12 pin are
as follows:
Pin No.
Pin Definition
Description
1
D0+ (DA+)
Positive bi-directional data of
Gigabit Ethernet group 1
2
D0- (DA-)
Negative bi-directional data
of Gigabit Ethernet group 1
3
D1+ (DB+)
Positive bi-directional data of
Gigabit Ethernet group 2
4
D1- (DB-)
Negative bi-directional data
of Gigabit Ethernet group 2
5
D3+ (DD+)
Positive bi-directional data of
Gigabit Ethernet group 4
6
D3- (DD-)
Negative bi-directional data
of Gigabit Ethernet group 4
3
4
Pin No.
NC
GND
7
8
【Checking LED Indicator】
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table
below:
LED
P1/P2
ALM
RUN
LINK
(E1-E16,
G1-G20)
POE
(E1-E16,
G1-G16)
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
Pin Definition
Description
D2- (DC-)
Negative bi-directional data
of Gigabit Ethernet group 3
D2+ (DC+)
Positive bi-directional data of
Gigabit Ethernet group 3
Indicate Description
P1/2 is connected and running
ON
normally
P1/2 is disconnected and running
OFF
abnormally
ON
Port link has alarm
OFF
Port link has no alarm
The device is powering on or the
ON
device is abnormal.
The device is powered off or the
OFF
device is abnormal.
Blinking 1 time per second, system
Blinking
is running normally
Ethernet port has established a valid
ON
network connection
Ethernet port
is in an active
Blinking
network status
Ethernet port has not established
OFF
valid network connection
POE port is powering other PD
ON
devices normally
POE port is not powering other PD
OFF
devices
way of logging in to device's configuration interface via IE
browser is shown as below:
Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed.
Enter device's IP address in the address bar of the
computer browser.
Enter device's username and password in the login
window as shown below.
Click "Login" button to login to the WEB interface of
the device.
Note:
The default IP address of the device is "192.168.1.254".
The default user name and password of the device are
"admin".
If the username or password is lost, user can restore it to
factory settings via management software; all modified
configurations will be cleared after restoring to factory
settings, so please backup configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other