If the gas pressure is different from the regulations, a pressure regulator that meets national and
government standards must be installed at the source. To complete the conversion, please follow
the steps below,
A) Replace the burner nozzle
B) Adjust the level of the burner flame
C) Leak test
A) Replace the Burner Nozzle
5 LPG nozzles in the package and 5 installed NG nozzles on the gas stove
B) Adjust the Level of the Burner Flame
When switching from one gas to another, the min flow rate must be adjusted so that the
flame does not go out. The adjustment steps are as follows,
Light up the burner
Turn the knob to minimum level
Adjustment screw is located in the center of the shaft (Fig.9). Please remove the
control knob to access it.
Use the largest 0.12" (3 mm) diameter screwdriver and turn the screw inside it until
the correct setting is obtained.screwdriver, turn the screw inside the screw until the
correct setting is obtained.