Dametric BRM-DM1 Panduan Pengguna - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Unit Kontrol Dametric BRM-DM1. Dametric BRM-DM1 10 halaman. Gms basic refiner module
Juga untuk Dametric BRM-DM1: Panduan Instalasi (6 halaman)

Dametric BRM-DM1 Panduan Pengguna
Dametric AB
5

Parameter description

5.1

GMS/BRM-DM1/2

BRM GMS System
BRM Can Node no.
BRM Ind.bus type
BRM Serial no.
BRM HW. Rev.no.
BRM DCS clock
BRM Test func.
BRM Date
5.2

CAN-Eth.-Conv.

The function is only valid and shown in a BRM-DM2.
CEC Off/ON/On-Al
CEC IP Address
CEC IP Mask
5.3

Rotor position

POM Off/On/On+Al
POM Direction
POM Ratio
POM Al.Lim. 1HH
POM Al.Lim. 2H
POM Al.Lim. 3L
POM Zero calibr.
POM Span calibr.
POM Work mode
5.4

Ref. vibration

VIM Off/On/On+Al
VIM Al.Lim. 1HH
VIM Al.Lim. 2H
5.5

Touch vibration

TVD Off/On/On+Al
TVD Sens. Idle
TVD Sens. Prod.
TVD Al.lim.1 Hg2
TVD Al.lim.2 Hg1
TVD Al.lim.3 Lg2
TVD Al.lim.4 Lg1
TVD Pro.adj.sen.
BRM-DM12 UM EN.docx
BRM-DM1/2
GMS measure system: 1:GMS-V1T01, 2:GMS-V1A01, 3:GMS-V1A02, 4:GMS-
V2A01, 5:GMS-V2T01, 6:GMS-V1X01, 7:GMS-V1X02.
Node number, normal 1, use 2 for flats side in a CD-refiner. (GMS-V2A01 and
GMS-V2T01).
0=no bus, 1= Profinet, 2=Profibus, 3=Ethernet IP.
The unit serial number.
Actual hardware revision.
Synch value from DCS/PLC over the industrial bus. 0 means no contact, 1-255 is a
value that increases continuously.
Test function (not used).
Date and time.
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
IP-address
IP-mask.
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
Direction, set to 0 or 1 depending of the type and thread of the control rod.
Ratio, set 1.00 for a flat refiner and like 0.20 for a conical.
Alarm limit 1, high-high.
Alarm limit 2, high.
Alarm limit 1, low.
Zero calibration, see the calibration manual for actual measure system.
Span calibration, see the calibration manual for actual measure system.
Shows alternately distance, and speed for the latest rotor travel.
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
Alarm limit 1, high-high.
Alarm limit 2, high.
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
Sensitivity at idle.
Sensitivity at production.
Alarm limit 1, idle, high-high.
Alarm limit 2, idle, high.
Alarm limit 3, production, high-high.
Alarm limit 4, production, high.
Adjusted sensitivity at production. The value can also be controlled from an external
source, like an industrial bus.
Feb. 18, 2020
User manual