Appendix A: Technical Data
A
Technical Data
PROFINET specification
PROFINET functionality
Isochronous cycle times
Maximum I/O data
Ethernet
®
Anybus
X-gateway
PROFINET
2.32
Isochronous Real-Time (IRT) communication
Conformance supporting Class A, B and C
Media Redundancy Protocol (MRP) support
Discovery and Configuration Protocol (DCP) support
Acyclic Data exchange (Record Data Requests)
Asset Management
0.250 ms to 16 ms
Up to 512 byte in each direction
100 Mbit/s, full duplex (fixed)
Dual port cut-through switch, RJ45 connectors
Ethernet Transport Provider support
®