SETTINGS
Hold and press
for 1 second to enter Settings Mode. SETUP should
appear in the display.
Press
to enter Auto-off options and press
to select Auto-off option.
Auto‐Off can be set to 0 (disabled), 5 (5min),
o
15 (15min), 30 (30min) and 60 (60min).
Press
to enter Auto-Zero options and press
to select Auto-Zero option.
o
Auto‐Zero can be set to 0 (disabled), 2
(2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20 (20%F.S.),
50 (50%F.S.).
Press
press
to select Manual Zero option.
o
Manual‐Zero can also be set to 0 (disabled),
2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20
(20%F.S.), 50 (50%F.S.)
Press
to enter Backlight options and press
to select Backlight option.
o
Backlight can be set to off (disabled), 5
(5sec), 15 (15sec), 30 (30sec), 60 (60sec) and on (never).
o
When Backlight is set to 5, 15, 30, or 60, the scale will turn off the
backlight if the scale is stable and no activities within the set
parameters (enumerated above).
o
When Backlight is set to off, the backlight is disabled and will never
turn on.
8 |
ANYLOAD OCSL Mini Type Crane Scale User's Guide
and
keys simultaneously
to enter Manual-Zero options and