Abtech STR1 Series Petunjuk Pemasangan, Pengoperasian, dan Pemeliharaan - Halaman 3

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan, Pengoperasian, dan Pemeliharaan untuk Lampu luar ruangan Abtech STR1 Series. Abtech STR1 Series 6 halaman.

IOM-STR1
6. LED Fitting and Replacement
The STR1 Roadway lantern range with regards to the LED array is a maintainable unit. In the event of a failure,
the failure must be reported to Abtech as per the warranty agreement.
Spares/ replacements are available, see product datasheet.
Maintenance
1. Visual Inspection
Visually inspect the luminaire for signs of water ingress or loose screws,
Check operation of LED by powering up the unit, leave the unit powered for at least an hour and re-inspect for
any failures.
2. Internal; Inspection
Remove the polycarbonate cover and check state of gasket for tears or dirt. Replace as necessary (see below)
Check tightness of cable gland and tighten as necessary.
Check tightness of all terminal screws (if applicable).
Check for any signs of water ingress and remedy as necessary.
Check condition of all wiring and electrical components for signs of arcing or overheating.
Refer to Abtech technical department for advice if any components are in doubt.
Refit glass cover and tighten screws.
3. Fault Finding
Any fault finding must be carried out with the luminaire de energised and without a flammable atmosphere
present.
Generally, LED drivers are very reliable and faults are generally the result of loose cabling. If after checking the
wiring the fault is still present, please refer to Abtech technical department for assistance.
4. Gasket Replacement
The unit gasket is one-piece silicone rubber and can only be obtained from Abtech. The old gasket should be
removed and any traces of sealant cleaned off. The area where the gasket is situated should be clean and free
from grease. The gasket should then be fitted to the enclosure. The glass cover should then be re-fitted and
the eight glass screws tightened evenly to ensure constant and even compression of the gasket.

Luminaire Dimensions

1. Luminaire external dimensions
Abtech Ltd
Newhall Road
Sheffield, S9 2QJ
United Kingdom
IOM-STR1 ABTQ210.docx
Page 3 of 6
t : +44 (0) 114 244 2424
f : +44 (0) 114 243 4312