Concoa 78 Panduan Petunjuk Pemasangan dan Pengoperasian - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pengoperasian untuk Alat Ukur Concoa 78. Concoa 78 8 halaman. Gas mizer
e. Purge lines individually, pressurize, and test for leaks at valve seats,
valve stem packings, hose connections, and pilot light connections
with an approved oxygen compatible leak detection fluid.
OPERATION
Pilot Light
With the torch off the hanger rod, turn the pilot light adjusting needle
valve counterclockwise and immediately light the pilot with a sparklighter.
Adjust the flame with the valve until satisfactory.
Use
Use the torch as usual but when through, instead of closing the torch
valves, place the torch on the hanger rod to extinguish the flame. (Point
flame away from bench as torch is hung.) For reuse, remove torch from
hanger rod and without delay relight at pilot flame.
Pressure Settings
The Gas Mizer does not affect regulator pressure settings for the torch.
Use the same pressure settings at each regulator, as if this device were not
in the torch system.
Hanger Rod Adjustment
When placing the Mizer in operation, the hanger rod should be adjusted
so that the hand torch will shut off the fuel gas and oxygen valves with its
own weight:
a. Close the pilot valve by turning the pilot valve T-handle clockwise
until it stops. Tighten only enough to ensure a tight seal.
b. With the torch off the hanger, adjust pressures and flames.
c. When the torch is placed on the hanger rod, the flames should
shut off. If the flames to do not shut off, perform the following
steps.
d. Loosen the hanger rod adjustment screw and slide the hanger rod
and torch to a point where the valves shut off fuel gas and oxygen
supplies.
e. Tighten the hanger rod adjustment screw and turn off the fuel gas
and oxygen supplies.
f.
Readjust, if necessary, the seat adjusting screws. Gases shutting
off simultaneously, flashing or popping can be eliminated by lag-
ging the fuel adjustment screw.
4