5. Wait 15 to 20 seconds and the unit will return to the "run" mode.
SENSOR PROGRAMMING-ENABLE SET POINT 2
NOTE: ALL BUTTON PRESSES MUST BE DONE WITHIN 15 SECONDS
1. Press and release the Mode/Enter button until OU2 is displayed. (3 presses )
2. Press and hold SET button until Hno is displayed, then release.
3. Press and release the Mode/Enter button to confirm.
4. Wait 15 to 20 seconds and the unit will return to the "run" mode.
SENSOR PROGRAMMING-SET POINT 2 (
NOTE: ALL BUTTON PRESSES MUST BE DONE WITHIN 15 SECONDS
1. Press and release the Mode/Enter button until SP 2 is displayed. (4 presses)
2. Press and hold the SET button until the desired distance for the second event is displayed, then release.
3. NOTE: Minimum distance is 1 meter (3.28 feet).
4. Press and release the Mode/Enter button once to confirm. The display will show SP 2.
5. Wait 15 to 20 seconds and the unit will return to the "run" mode.
**REPEAT STEPS FOR 2
YOUR LASER COLLISON AVOIDANCE SYSTEMS SHOULD NOW BE READY TO OPERATE. PLEASE ENSURE THAT THE
LED'S ON THE CONTROL UNIT LIGHT WHEN CRANE IS MOVED TO EACH SET POSITION.
FACTORY RESET-ONLY IF REQUIRED
1. In the event that improper selections were made during the previous sensor programming steps, it may
be necessary to reset the unit to factory settings. Perform the following steps ONLY if required or the
sensor is not responding as intended.
2. Press and release the Mode/Enter button until EF is displayed. (multiple presses required)
3. Press and release the SET button once.
4. Press and release the Mode/Enter button until rES is displayed
5. Press and hold SET button until ---- (4 dashes) is displayed
6. Confirm by pressing the Mode/Enter button once.
7. After performing the factory reset you must repeat the SENSOR PROGRAMMING steps outlined in the
steps above.
*****The Duct-O-Wire CAS-2L100 Duplex includes two extra relays that make it possible to split the 2
from your pendant into two separate signals to the VFD drive. You may need to change your drive settings
from infinitely variable to stepping. Depending on your drive it may be possible using the extra contacts to use
the infinitely variable setting on your drive. However; this would be decided by a qualified technician. *****
The C1, C2 contacts are rated 120VAC. If you need a 24VDC rated coil please consult factory.
The Q1, Q2, Q3, Q4 relays are controlled by a 24VDC laser.
C1 is controlled from the Q2 Forward relay.
C2 is controlled from the Q4 Reverse relay.