Duerkopp Adler 175 Panduan Aksesori - Halaman 7
Jelajahi secara online atau unduh pdf Panduan Aksesori untuk Mesin Jahit Duerkopp Adler 175. Duerkopp Adler 175 8 halaman. Fitting instructions - power supply for sewing lamps kit 9850 001089
Juga untuk Duerkopp Adler 175: Panduan Aksesori (8 halaman)
Fitting instructions - Power supply for sewing lamps
6
5
2
Ausgabe/Edition:
Änderungsindex
12.2008
Rev. index: 00.0
Anbauanleitung Netzteil für Nähleuchten
Teilesatz / Kit 9850 001089
1
–
Push the cable 5 of the power supply from the back through the
control box 1.
–
Put the cable through the rubber grommet 6 and insert it in the
control box.
–
Insert the strands of the cable in the spring terminal 7.
Press on the spring terminal to release the openings and insert
the strands of the cable.
4
1
–
Put the front plate 2 of the control box again and fasten it with the
screws 4.
–
Fix the control box to the front plate 2 again using the four
screws 3.
3
Printed in Germany
Teile-Nr./ Part-No.:
0791 100701
6
7
2
1
Blatt:
7 von 8