[Installation]
The installation and removal methods are the same
for master and slave units.
Hook the movable tab A on the DIN rail.
Push the unit in the direction of C until the xed tab D on the opposite side clicks.
D
[Removal]
Push the unit in the direction of B and free the xed tab D from the DIN rail.
While keeping the unit pushed, pull it up in the direction of G to lift the body and
take it off the rail.
B
D
G
[Installation Location]
- Locations where this product is not directly subject to vibration or shock
- Locations where this product is not directly exposed to dust
- Locations where this product is not directly exposed to conductors, such as
metal chips or spatters
- Locations without condensation
- Locations where the atmosphere is free of corrosive gases, ammable gases,
and sulfur
- Locations far from high-voltage or high-current cables
- Locations far from servos, inverters, and other cables and controllers that
generate high-frequency noise
[Notes on the Use]
To connect the unit to the transmission line or add a new slave unit to the master
unit, always stop the transmission signal.
If the connection is made with a live wire, the unit may stop working by
interpreting the chattering caused during the connection as an error.
[Expansion]
Master Slave
Install the unit vertically so
that the movable tab faces
downward.
Up
A
Up
A
-L*F1011 5/11-
Slave units can be additionally connected to the master unit.
Remove the connector cover on the master unit and connect a slave
unit to the built-in expansion connector.
Expansion
connector
Slave
32 units max.
Up to 31 units of LB-F1011 can be connected to one unit of LA-F1011.
Speci cations of LA-F1011 and LB-F1011 are as follows:
■Current consumption
DP-DN
LA-F1011
(common)
LB-F1011
24V-0V
■Number of occupied points
LA-F1011
(common)
LB-F1011
The block with 31 units of LB-F1011 connected to LA-F1011 occupies
32 points of input.
DP-DN current consumption is 60.8mA.
If ber inputs of 32 or more optical axes are required, provide an
additional block.
When a system comprises LA-F1011 and LB-F1011 only, the maximum
number of connectable units is 128 per system.
Remove the connector cover.
(Do not misplace the cover.)
Master
1.9mA
25mA
1 point
1 point