ROUBLESHOOTING
General Procedures
3.1
Truck System Requirements
3.1-1
• Truck hydraulic pressure should be within the range
shown in Specifications, Section 5.1. PRESSURE TO
THE SIDESHIFTER MUST NOT EXCEED 3500 psi
(245 bar).
• Truck hydraulic flow should be within the volume range
shown in Specifications, Section 5.1.
• Hydraulic fluid supplied to the sideshifter must meet the
requirements shown in Specifications, Section 5.1.
Tools Required
3.1-2
In addition to a normal selection of hand tools, the following
are required:
• Inline Flow Meter Kit:
20 GPM (80 L/min.) - Cascade part no. 671477
• Pressure Gauge Kit:
3000 psi (200 bar) - Cascade part no. 671212
• Assorted fittings, lines, drain hoses and quick-couplers
as required.
Troubleshooting Chart
3.1-3
Determine All The Facts – It is important that all
the facts regarding the problem are gathered before
beginning service procedures. The first step is to
talk to the equipment operator. Ask for a complete
description of the malfunction. The following
guidelines can then be used as a starting point to
begin troubleshooting procedures:
Sideshift Circuit
• Frame will not sideshift.
• Frame sideshifts slowly.
To correct these problems, see Section 3.3.
6020275-R2
WARNING: Before servicing any
hydraulic component, relieve pressure in
the system. Turn the truck off and move
the truck auxiliary control valves several
times in both directions.
After completing any service procedure, test the
attachment through several cycles. First test the
attachment empty to bleed any air trapped in the
system to the truck tank. Then test the attachment
with a load to be sure it operates correctly before
returning to the job.
Stay clear of the load while testing. Do not raise the
load more than 4 in. (10 cm) off the floor while testing.
Flow Meter Kit 671477
No. 8-12 JIC/
O-Ring
No. 6-8 JIC
Reducer
Pressure Gauge Kit 671212
Pressure
Gauge
★
No. 6-6 Hose
GA0014.eps
No. 4-6 Pipe/JIC
Diagnostic Quick-Disconnects
Female JIC Thread
QD Coupler:
AC0127.eps
No. 4 (Part No. 210385)
★
No. 6 (Part No. 678591)
★ Included in Diagnostics Kit 394382
Flow Meterc
GA0013.eps
No. 6 and No. 8
JIC Swivel Tee
★
No. 6-8 JIC
No. 4, No. 6
★
Reducer
and No. 8
JIC/O-Ring
Male Straigh Thread
O-Ring Coupler:
No. 4 (Part No. 212282)
★
No. 5 (Part No. 210378)
No. 6 (Part No. 678592)
3